A mathematical model of aerosol holding chambers.

M Zak1, J Madsen, E Berg, J Bülow, H Bisgaard.   

Abstract

A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London, Ontario, Canada), NebuChamber (Astra, Södirtälje, Sweden) and Nebuhaler (Astra) adapted for babies. The dose of fluticasone proportionate delivered by the Babyhaler (Glaxco Wellcome, Oxbridge, Middlesex, UK) was 80% of that predicted, probably because of incomplete priming of this spacer. Of the above-mentioned factors, initial loss of aerosol by impact on the chamber wall is most important for the efficiency of a spacer. With a VT of 195 mL, the AeroChamber and Babyhaler were emptied in two breaths, the NebuChamber in four breaths, and the Nebuhaler in six breaths. Insufficiencies of the expiratory valves were demonstrated by comparison of pressure flow curves during "inspiratory" flow with and without occluded expiratory openings. Insufficient inspiratory valves were demonstrated by comparison of "expiratory" pressure flow curves with and without occluded inspiratory openings. With children breathing through the spacers, mask pressure variations were generally on the same order as that seen with the mechanical respiratory, supporting the clinical relevance of the in vitro findings.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10623335     DOI: 10.1089/jam.1999.12.187

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  5 in total

1.  Bioavailability of inhaled fluticasone propionate via chambers/masks in young children.

Authors:  K Blake; R Mehta; T Spencer; R L Kunka; L Hendeles
Journal:  Eur Respir J       Date:  2011-09-20       Impact factor: 16.671

2.  Effect of plastic spacer handling on salbutamol lung deposition in asthmatic children.

Authors:  Brian J Lipworth; Daniel K C Lee; Jacob Anhøj; Hans Bisgaard
Journal:  Br J Clin Pharmacol       Date:  2002-11       Impact factor: 4.335

3.  In Vitro Determination of Respimat® Dose Delivery in Children: An Evaluation Based on Inhalation Flow Profiles and Mouth-Throat Models.

Authors:  Deborah Bickmann; Wolfgang Kamin; Ashish Sharma; Herbert Wachtel; Petra Moroni-Zentgraf; Stefan Zielen
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2015-06-22       Impact factor: 2.849

Review 4.  Use of inhaler devices in pediatric asthma.

Authors:  Fernando Maria De Benedictis; David Selvaggio
Journal:  Paediatr Drugs       Date:  2003       Impact factor: 3.022

5.  A Handling Study to Assess Use of the Respimat(®) Soft Mist™ Inhaler in Children Under 5 Years Old.

Authors:  Wolfgang Kamin; Marion Frank; Sabine Kattenbeck; Petra Moroni-Zentgraf; Herbert Wachtel; Stefan Zielen
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2015-04-06       Impact factor: 2.849

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.