Literature DB >> 10620308

Cell volume measurement using scanning ion conductance microscopy.

Y E Korchev1, J Gorelik, M J Lab, E V Sviderskaya, C L Johnston, C R Coombes, I Vodyanoy, C R Edwards.   

Abstract

We report a novel scanning ion conductance microscopy (SICM) technique for assessing the volume of living cells, which allows quantitative, high-resolution characterization of dynamic changes in cell volume while retaining the cell functionality. The technique can measure a wide range of volumes from 10(-19) to 10(-9) liter. The cell volume, as well as the volume of small cellular structures such as lamelopodia, dendrites, processes, or microvilli, can be measured with the 2.5 x 10(-20) liter resolution. The sample does not require any preliminary preparation before cell volume measurement. Both cell volume and surface characteristics can be simultaneously and continuously assessed during relatively long experiments. The SICM method can also be used for rapid estimation of the changes in cell volume. These are important when monitoring the cell responses to different physiological stimuli.

Mesh:

Year:  2000        PMID: 10620308      PMCID: PMC1300652          DOI: 10.1016/S0006-3495(00)76607-0

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  30 in total

1.  From molecules to cells: imaging soft samples with the atomic force microscope.

Authors:  M Radmacher; R W Tillamnn; M Fritz; H E Gaub
Journal:  Science       Date:  1992-09-25       Impact factor: 47.728

2.  Atomic force microscope.

Authors: 
Journal:  Phys Rev Lett       Date:  1986-03-03       Impact factor: 9.161

3.  Chemical imaging of surfaces with the scanning electrochemical microscope.

Authors:  A J Bard; F R Fan; D T Pierce; P R Unwin; D O Wipf; F Zhou
Journal:  Science       Date:  1991-10-04       Impact factor: 47.728

4.  bFGF and aFGF induce membrane ruffling in breast cancer cells but not in normal breast epithelial cells: FGFR-4 involvement.

Authors:  C L Johnston; H C Cox; J J Gomm; R C Coombes
Journal:  Biochem J       Date:  1995-03-01       Impact factor: 3.857

5.  Transmembrane ion movements elicited by sodium pump inhibition in Helix aspersa neurons.

Authors:  F J Alvarez-Leefmans; H Cruzblanca; S M Gamiño; J Altamirano; A Nani; L Reuss
Journal:  J Neurophysiol       Date:  1994-05       Impact factor: 2.714

6.  The human Na+-glucose cotransporter is a molecular water pump.

Authors:  A Meinild; D A Klaerke; D D Loo; E M Wright; T Zeuthen
Journal:  J Physiol       Date:  1998-04-01       Impact factor: 5.182

7.  Scanning ion conductance microscopy of living cells.

Authors:  Y E Korchev; C L Bashford; M Milovanovic; I Vodyanoy; M J Lab
Journal:  Biophys J       Date:  1997-08       Impact factor: 4.033

8.  Cell volume changes upon sodium pump inhibition in Helix aspersa neurones.

Authors:  F J Alvarez-Leefmans; S M Gamiño; L Reuss
Journal:  J Physiol       Date:  1992-12       Impact factor: 5.182

9.  Acute cell volume changes in anisotonic media affect F-actin content of HL-60 cells.

Authors:  K R Hallows; C H Packman; P A Knauf
Journal:  Am J Physiol       Date:  1991-12

10.  Measurement by confocal laser scanning microscopy of the volume of epidermal nuclei in thick skin sections.

Authors:  Q Zhu; P Tekola; J P Baak; J A Beliën
Journal:  Anal Quant Cytol Histol       Date:  1994-04       Impact factor: 0.302

View more
  25 in total

1.  Cell volume kinetics of adherent epithelial cells measured by laser scanning reflection microscopy: determination of water permeability changes of renal principal cells.

Authors:  K Maric; B Wiesner; D Lorenz; E Klussmann; T Betz; W Rosenthal
Journal:  Biophys J       Date:  2001-04       Impact factor: 4.033

2.  Simultaneous measurement of Ca2+ and cellular dynamics: combined scanning ion conductance and optical microscopy to study contracting cardiac myocytes.

Authors:  A I Shevchuk; J Gorelik; S E Harding; M J Lab; D Klenerman; Y E Korchev
Journal:  Biophys J       Date:  2001-09       Impact factor: 4.033

3.  Ion channels in small cells and subcellular structures can be studied with a smart patch-clamp system.

Authors:  Julia Gorelik; Yuchun Gu; Hilmar A Spohr; Andrew I Shevchuk; Max J Lab; Sian E Harding; Christopher R W Edwards; Michael Whitaker; Guy W J Moss; David C H Benton; Daniel Sánchez; Alberto Darszon; Igor Vodyanoy; David Klenerman; Yuri E Korchev
Journal:  Biophys J       Date:  2002-12       Impact factor: 4.033

4.  Measurement of the thickness and volume of adherent cells using transmission-through-dye microscopy.

Authors:  Jennifer L Gregg; Karen M McGuire; Daniel C Focht; Michael A Model
Journal:  Pflugers Arch       Date:  2010-08-19       Impact factor: 3.657

5.  N-Docosahexaenoylethanolamide promotes development of hippocampal neurons.

Authors:  Hee-Yong Kim; Hyun-Seuk Moon; Dehua Cao; Jeongrim Lee; Karl Kevala; Sang Beom Jun; David M Lovinger; Mohammed Akbar; Bill X Huang
Journal:  Biochem J       Date:  2011-04-15       Impact factor: 3.857

Review 6.  Three-dimensional confocal morphometry - a new approach for studying dynamic changes in cell morphology in brain slices.

Authors:  Alexandr Chvátal; Miroslava Anderová; Frank Kirchhoff
Journal:  J Anat       Date:  2007-05-07       Impact factor: 2.610

7.  Cytoskeleton remodelling of confluent epithelial cells cultured on porous substrates.

Authors:  Jan Rother; Matthias Büchsenschütz-Göbeler; Helen Nöding; Siegfried Steltenkamp; Konrad Samwer; Andreas Janshoff
Journal:  J R Soc Interface       Date:  2015-02-06       Impact factor: 4.118

Review 8.  Multifunctional scanning ion conductance microscopy.

Authors:  Ashley Page; David Perry; Patrick R Unwin
Journal:  Proc Math Phys Eng Sci       Date:  2017-04-12       Impact factor: 2.704

Review 9.  T-type Ca2+ channels in spermatogenic cells and sperm.

Authors:  Alberto Darszon; Arturo Hernández-Cruz
Journal:  Pflugers Arch       Date:  2014-03-06       Impact factor: 3.657

10.  A boundary delimitation algorithm to approximate cell soma volumes of bipolar cells from topographical data obtained by scanning probe microscopy.

Authors:  Patrick Happel; Kerstin Möller; Ralf Kunz; Irmgard D Dietzel
Journal:  BMC Bioinformatics       Date:  2010-06-15       Impact factor: 3.169

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.