Radial dose distribution, dose to water and dose rate constant for monoenergetic photon point sources from 10 keV to 2 MeV:EGS4 Monte Carlo model calculation.

G Luxton1, G Jozsef.   

Abstract

A comprehensive set of dose distributions from monoenergetic photon-emitting isotropic point sources in a medium can be used as a reference database for the dosimetry of photon emitter sources in that medium. Data of this type for water over the photon energy range from 15 keV to 2 MeV have been published based on calculations using a one-dimensional photon transport model. The present work, based on a previously published EGS4 Monte Carlo code, updates the classic data set of Berger and provides more extensive calculations than previously available. Air kerma strength per unit photon emission rate from an isotropic point emitter is obtained as a function of energy using published data for mass energy absorption coefficients. The TG-43 dose rate constant for water as a function of energy is calculated for monoenergetic photon emitters as the ratio of dose rate to water at 1 cm to air kerma strength for unit photon emission rate. Results for the radial dose distribution agree well with the data of Berger between 40 and 400 keV. For energies > or =500 keV, a previously undescribed buildup region for the radial dose function is identified. Thickness of the buildup region ranges from 1 mm at 500 keV to 8 mm at 2 MeV. Between 15 and 30 keV, the radial dose function within a few millimeters of the emitter is calculated to be 4%-5% higher than values derived from Berger's data. The maximum dose rate constant for monoenergetic photon emitters occurs at an energy of 60 keV, and has the value 1.355 cGy h(-1)U(-1), where U is the unit of air kerma strength, 1 microGy m2 h(-1). This would correspond to the maximum hypothetical dose rate constant for a brachytherapy photon source emitting photons of energy < or =2 MeV.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10619236     DOI: 10.1118/1.598790

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Dosimetric characterization of the GammaClip™ 169Yb low dose rate permanent implant brachytherapy source for the treatment of nonsmall cell lung cancer postwedge resection.

Authors:  Blake Currier; John J Munro; David C Medich
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

2.  Monte Carlo-based revised values of dose rate constants at discrete photon energies.

Authors:  T Palani Selvam; Vandana Shrivastava; Ghanashyam Chourasiya; D Appala Raju Babu
Journal:  J Med Phys       Date:  2014-01

3.  Technical Note: Monte Carlo calculations of the AAPM TG-43 brachytherapy dosimetry parameters for a new titanium-encapsulated Yb-169 source.

Authors:  Francisco J Reynoso; John J Munro Iii; Sang Hyun Cho
Journal:  J Appl Clin Med Phys       Date:  2017-06-06       Impact factor: 2.102

4.  Synthesis and Characterization of a New Nanocomposite Film Based on Polyvinyl Alcohol Polymer and Nitro Blue Tetrazolium Dye as a Low Radiation Dosimeter in Medical Diagnostics Application.

Authors:  Saleh Alashrah; Yassine El-Ghoul; Mohammed Ahmed Ali Omer
Journal:  Polymers (Basel)       Date:  2021-05-31       Impact factor: 4.329

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.