Maximum-likelihood reconstruction with ordered subsets in bone SPECT.

D Blocklet1, A Seret, N Popa, A Schoutens.   

Abstract

UNLABELLED: This study was aimed at determining whether the ordered-subset expectation maximum (OSEM) is more effective than filtered backprojection (FBP) for bone SPECT in the routine clinical context.
METHODS: Fifty-seven consecutive bone SPECT studies were analyzed. They included pelvic and lumbar spine, thoracolumbar spine, head and neck, feet and shoulders. A 64-projection SPECT study was acquired over 360 degrees by single-head cameras 2-3 h after the injection of 750 MBq 99mTc-methylene diphosphonate. Three observers compared the OSEM and FBP reconstructed images.
RESULTS: Streak artifacts, always present with FBP, were rarely generated with the OSEM. When present (n = 24), artifacts associated with negative values near hyperactivities in FBP were not generated with the OSEM in 67% of the cases (n = 16), permitting a satisfactory interpretation of these regions. In half of the other cases (17%, n = 4/24), interpretation was precluded. In only one case did the three observers agree that more hyperactivities were seen with the OSEM. Ninety-six percent of the OSEM pictures were superior or equal to FBP for anatomic resolution and were clearly better in 12% of the cases. The extent of the lesion with the OSEM seemed better or equally defined in 96% and clearly better in 14% of the cases. The low-activity regions were better or equally visualized in all cases and were clearly better seen in 23% of the cases. The quality of the pictures was found to be better or superior with the OSEM in 98% of the cases and definitely better in 65% of the cases.
CONCLUSION: Replacement of FBP by the OSEM in bone SPECT would be beneficial to clinical practice.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10616874

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  3 in total

1.  Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study.

Authors:  Fabrice Gutman; Isabelle Gardin; Nicolas Delahaye; Hervé Rakotonirina; Anne Hitzel; Alain Manrique; Dominique Le Guludec; Pierre Véra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-23       Impact factor: 9.236

2.  Optimization of Ordered Subset Expectation Maximization Reconstruction for Reducing Urinary Bladder Artifacts in Single-photon Emission Computed Tomography Imaging.

Authors:  A M Katua; A O Ankrah; M Vorster; A van Gelder; M M Sathekge
Journal:  World J Nucl Med       Date:  2011-01

3.  On the optimization of bone SPECT/CT in terms of image quality and radiation dose.

Authors:  Monika Tulik; Piotr Tulik; Teresa Kowalska
Journal:  J Appl Clin Med Phys       Date:  2020-10-27       Impact factor: 2.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.