Literature DB >> 10616156

Monte Carlo calculated output factors of a Leksell Gamma Knife unit.

J Y Cheung1, K N Yu, R T Ho, C P Yu.   

Abstract

The Leksell Gamma Knife is a standard radiosurgical tool for treating brain lesions by directing beams of gamma radiation to a specific region. The diameter of the gamma beams is confined by collimator systems and available collimator sizes are 4, 8, 14 and 18 mm. The reduction in dose rate for each collimator helmet is called the output factor (OPF). Experimental determination of OPFs is difficult due to the extremely narrow beams for which the dose is determined. In the present work, the PRESTA version of the EGS4 Monte Carlo code was used to obtain relative OPFs for the Leksell Gamma Knife for collimator sizes of 14, 8 and 4 mm (relative to that of the 18 mm collimator). A spherical probe with a radius of 1 mm was utilized in this computer experiment. Our Monte Carlo results gave OPFs of 0.974, 0.951 and 0.872 for the 14 mm, 8 mm and 4 mm collimators respectively, relative to the 18 mm collimator. Our calculated OPF for the 4 mm collimator helmet was more than 8% higher than the value currently used, but in good agreement with the average of experimental values obtained by various Gamma Knife centres throughout the world and with the value now recommended by the manufacturer, Elekta (Elekta Instrument AB, Skeppargatan 8, S-114 52 Stockholm, Sweden).

Entities:  

Mesh:

Year:  1999        PMID: 10616156     DOI: 10.1088/0031-9155/44/12/401

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification.

Authors:  Shih-Ming Hsu; Chao-Hsiung Hung; Yi-Jen Liao; Hsiao-Mei Fu; Jo-Ting Tsai; Yung-Hui Huang; David Y C Huang
Journal:  PLoS One       Date:  2017-01-03       Impact factor: 3.240

2.  Technical note: the effect of the 4-mm-collimator output factor on gamma knife dose distributions.

Authors:  John P Gibbons; Dimitris Mihailidis; Curtis Worthington; Hassaan Alkhatib; Raleigh Boulware; Robert Clark; Burke Dial; William Neglia
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

3.  Development of a Monte Carlo model for treatment planning dose verification of the Leksell Gamma Knife Perfexion radiosurgery system.

Authors:  Jiankui Yuan; Simon S Lo; Yiran Zheng; Jason W Sohn; Andrew E Sloan; Rodney Ellis; Mitchell Machtay; Barry Wessels
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

4.  A novel and effective method for validation and measurement of output factors for Leksell Gamma Knife® Icon™ using TRS 483 protocol.

Authors:  Swapna Lilly Cyriac; Jian Liu; Emel Calugaru; Jenghwa Chang
Journal:  J Appl Clin Med Phys       Date:  2020-09-06       Impact factor: 2.102

  4 in total