Randomized controlled trial of volume-targeted synchronized ventilation and conventional intermittent mandatory ventilation following initial exogenous surfactant therapy.

J D Mrozek1, E M Bendel-Stenzel, P A Meyers, D R Bing, J E Connett, M C Mammel.   

Abstract

We set out to evaluate the impact of volume-targeted synchronized ventilation and conventional intermittent mandatory ventilation (IMV) on the early physiologic response to surfactant replacement therapy in neonates with respiratory distress syndrome (RDS). We hypothesized that volume-targeted, patient-triggered synchronized ventilation would stabilize minute ventilation at a lower respiratory rate than that seen during volume-targeted IMV, and that synchronization would improve oxygenation and decrease variation in measured tidal volume (V(t)). This was a prospective, randomized study of 30 hospitalized neonates with RDS. Infants were randomly assigned to volume-targeted ventilation using IMV (n = 10), synchronized IMV (SIMV; n = 10), or assist/control ventilation (A/C; n = 10) after meeting eligibility requirements and before initial surfactant treatment. Following measurements of arterial blood gases and cardiovascular and respiratory parameters, infants received surfactant. Infants were studied for 6 hr following surfactant treatment. Infants assigned to each mode of ventilation had similar birth weight, gestational age, and Apgar scores at birth, and similar oxygenation indices at randomization. Three patients were eliminated from final data analysis because of exclusionary conditions unknown at randomization. Oxygenation improved significantly following surfactant therapy in all groups by 1 hr after surfactant treatment (P < 0.05). No further improvements occurred with time. Total respiratory rate was lowest (P < 0.05) and variation in tidal volume (V(t)) was least in the A/C group (P < 0. 05). Minute ventilation (V(')(E)), delivered airway pressures, respiratory system mechanics, and hemodynamic parameters were similar in all groups. We conclude that volume-targeted A/C ventilation resulted in more consistent tidal volumes at lower total respiratory rates than IMV or SIMV. Oxygenation and lung mechanics were not altered by synchronization, possibly due to the volume-targeting strategy. Of the modes studied, A/C, a fully-synchronized mode, may be the most efficient method of mechanical ventilator support in neonates receiving surfactant for treatment of RDS. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10613781     DOI: 10.1002/(sici)1099-0496(200001)29:1<11::aid-ppul3>3.0.co;2-5

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  5 in total

Review 1.  Update on modalities of mechanical ventilators.

Authors:  A Greenough
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-07       Impact factor: 5.747

2.  Volume-targeted modes of modern neonatal ventilators: how stable is the delivered tidal volume?

Authors:  Thomas Jaecklin; Denis R Morel; Peter C Rimensberger
Journal:  Intensive Care Med       Date:  2006-11-22       Impact factor: 17.440

Review 3.  New modes of mechanical ventilation in the preterm newborn: evidence of benefit.

Authors:  Nelson Claure; Eduardo Bancalari
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-09-05       Impact factor: 5.747

Review 4.  Mechanical ventilation modes for respiratory distress syndrome in infants: a systematic review and network meta-analysis.

Authors:  Changsong Wang; Libo Guo; Chunjie Chi; Xiaoyang Wang; Lei Guo; Weiwei Wang; Nana Zhao; Yibo Wang; Zhaodi Zhang; Enyou Li
Journal:  Crit Care       Date:  2015-03-20       Impact factor: 9.097

Review 5.  Synchronized mechanical ventilation for respiratory support in newborn infants.

Authors:  Anne Greenough; Thomas E Rossor; Adesh Sundaresan; Vadivelam Murthy; Anthony D Milner
Journal:  Cochrane Database Syst Rev       Date:  2016-09-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.