Literature DB >> 10609996

Phantom and in vivo study of the Look-Locher T1 mapping method.

M Karlsson1, B Nordell.   

Abstract

This paper describes and tests the LL-EPI method for obtaining quantitative T1 estimates in a few seconds thereby allowing dynamic T1 studies. It is shown that the method works even when there is an inflow into the imaged volume, e.g., in a vessel. No calibration is needed. The method has been tested in a phantom study with several different scan parameter set-ups, with and without inflow. The method shows robustness and individual scan parameters and inflow rates do not influence the ability to calculate the Gd-DTPA concentration. Linearity prevail between the measured 1/T1 and the Gd-DTPA concentration in the range 150 < T1 < 2500 ms. In a dynamic Gd-DTPA phantom study, it was shown that the dynamic LL-EPI T1 mapping technique was three times more sensitive than the signal from a T2*-weighted EPI sequence. In an in vivo study, dynamic T1 mapping of the Gd-DTPA uptake in a meningioma was performed. Inspection of the uptake curves indicates that the method is feasible in clinical perfusion studies.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10609996     DOI: 10.1016/s0730-725x(99)00078-8

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

1.  Automatic segmentation of subcutaneous mouse tumors by multiparametric MR analysis based on endogenous contrast.

Authors:  Stefanie J C G Hectors; Igor Jacobs; Gustav J Strijkers; Klaas Nicolay
Journal:  MAGMA       Date:  2014-11-27       Impact factor: 2.310

2.  Rapid volumetric T1 mapping of the abdomen using three-dimensional through-time spiral GRAPPA.

Authors:  Yong Chen; Gregory R Lee; Gunhild Aandal; Chaitra Badve; Katherine L Wright; Mark A Griswold; Nicole Seiberlich; Vikas Gulani
Journal:  Magn Reson Med       Date:  2015-05-18       Impact factor: 4.668

3.  Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

Authors:  Wen Li; Mark Griswold; Xin Yu
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

4.  Effects of T2 * on accuracy and precision of dynamic T1 measurements using the single reference variable flip angle method: a simulation study.

Authors:  Michael A Malmberg; Henrik Odéen; Dennis L Parker
Journal:  Med Phys       Date:  2022-02-15       Impact factor: 4.071

5.  Multiparametric MRI analysis for the identification of high intensity focused ultrasound-treated tumor tissue.

Authors:  Stefanie J C G Hectors; Igor Jacobs; Gustav J Strijkers; Klaas Nicolay
Journal:  PLoS One       Date:  2014-06-13       Impact factor: 3.240

6.  Megalencephalic leukoencephalopathy with subcortical cysts is a developmental disorder of the gliovascular unit.

Authors:  Alice Gilbert; Xabier Elorza-Vidal; Armelle Rancillac; Audrey Chagnot; Mervé Yetim; Vincent Hingot; Thomas Deffieux; Anne-Cécile Boulay; Rodrigo Alvear-Perez; Salvatore Cisternino; Sabrina Martin; Sonia Taïb; Aontoinette Gelot; Virginie Mignon; Maryline Favier; Isabelle Brunet; Xavier Declèves; Mickael Tanter; Raul Estevez; Denis Vivien; Bruno Saubaméa; Martine Cohen-Salmon
Journal:  Elife       Date:  2021-11-01       Impact factor: 8.140

  6 in total