Literature DB >> 10602927

Liver-specific imaging with SHU 563A: diagnostic potential of a new class of ultrasound contrast media.

A Bauer1, M Blomley, E Leen, D Cosgrove, R Schlief.   

Abstract

The purpose of this study was to evaluate the imaging properties and diagnostic potential of the novel polymeric ultrasound contrast agent SHU 563 A. After i. v. injection, the agent circulates in the blood pool for about 10 min and is then subsequently sequestered by the RES cells predominantly in the liver. The acoustic emission capabilities enable a very sensitive detection during the blood pool phase and after uptake in the RES cells, contributing to differential diagnosis as well as detection of liver lesions. During a multicenter study, 28 patients with liver lesions were examined. In all patients the results were compared to baseline ultrasound and Contrast enhanced Spiral CT. With respect to lesion size and location, very good agreement between SHU 563 A ultrasound and Spiral CT was achieved. Additional lesions could be shown in the RES phase by SHU 563 A enhanced ultrasound. 26 further patients were examined in other indications. The results in all 54 patients indicate good safety and tolerance of SHU 563 without limitations for diagnostic use. SHU 563 A enhanced ultrasound adds significantly to the detection and delineation of focal liver lesions by improving conspicuity due to RES based contrast after uptake.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10602927     DOI: 10.1007/pl00014072

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  4 in total

Review 1.  Recent applications of ultrasound: diagnosis and treatment of hepatocellular carcinoma.

Authors:  Hitoshi Maruyama; Masaaki Ebara
Journal:  Int J Clin Oncol       Date:  2006-08       Impact factor: 3.402

2.  Contrast-enhanced ultrasound: Extended role outside 'regulations'.

Authors:  Paul S Sidhu
Journal:  Ultrasound       Date:  2016-02-09

Review 3.  Functional micro/nanobubbles for ultrasound medicine and visualizable guidance.

Authors:  Chen Zhang; Yihong Li; Zhe Liu; Xinyong Ma; Wenxin He; Chenxi Liu
Journal:  Sci China Chem       Date:  2021-02-25       Impact factor: 9.445

Review 4.  Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery.

Authors:  Vera Paefgen; Dennis Doleschel; Fabian Kiessling
Journal:  Front Pharmacol       Date:  2015-09-15       Impact factor: 5.810

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.