Laser thrombolysis using long pulse frequency-doubled Nd:YAG lasers.

J A Viator1, S A Prahl.   

Abstract

BACKGROUND AND
OBJECTIVE: Laser thrombolysis is a means for clearing blood clots in occluded arteries. Many researchers have studied the mechanisms of clot ablation, and research clinicians have used the technique to treat myocardial infarction with a number of different laser systems. Specifically, a 1-microsec pulsed dye laser has been used clinically to remove blood clots in coronary arteries. As a comparative study, the ablation characteristics of lasers with pulse durations in the ranges of 50-150 microsec and 2-10 msec were investigated. Two frequency-doubled Nd:YAG lasers at 532 nm were used in this study. Ablation threshold and ablation efficiency of gel phantoms and thrombus using these two lasers were measured and compared with the results of the pulsed dye laser. The pulsed dye laser in this study operated at 522 nm. STUDY DESIGN/
MATERIALS AND METHODS: Gelatin samples with 150 cm(-1) absorption coefficient at 532 nm and animal clot were confined to 3-mm silicone tubes to measure ablation parameters. Additional samples with 150 cm(-1) absorption coefficient at 522 nm were prepared for use with the pulsed dye laser. A fluorescence technique and photographic bubble detection were used to determine ablation threshold. A spectrophotometric technique was used to determine ablation efficiency.
RESULTS: The ablation threshold of the gel phantoms for all three lasers was determined to be 17 +/- 2 mJ/mm(2). Ablation efficiency for the gel phantoms was 1.7 +/- 0.1 microg/mJ. Clot had an ablation efficiency of 2.9 +/- 1.0 microg/mJ.
CONCLUSIONS: Ablation threshold and efficiency are independent of laser pulse duration for 1-microsec, 50-150-microsec, and 2-10-msec pulses (P < 0.05). Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10602129     DOI: 10.1002/(sici)1096-9101(1999)25:5<379::aid-lsm3>3.0.co;2-b

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  3 in total

1.  A reconstituted in vitro clot model for evaluating laser thrombolysis.

Authors:  Abram D Janis; Lisa A Buckley; Abby N Nyara; Scott A Prahl; Kenton Gregory
Journal:  J Thromb Thrombolysis       Date:  2002-06       Impact factor: 2.300

2.  In vitro analysis of mechanism of pulsed-laser thrombolysis.

Authors:  Daisuke Yamashita; Yuji Matsumoto; Yoshinori Tamaoki; Yukio Ueda; Hiroyuki Okada; Toshiyuki Kawashima; Yutaka Yamashita; Teiji Nakayama; Kazuo Umemura
Journal:  PLoS One       Date:  2022-01-27       Impact factor: 3.240

3.  Noxious Stimulation Induces Acute Hemorrhage and Impairs Long-Term Recovery after Spinal Cord Injury (SCI) in Female Rats: Evidence Estrous Cycle May Have a Modulatory Effect.

Authors:  Rachel E Baine; David T Johnston; Misty M Strain; Melissa K Henwood; Jacob A Davis; Joshua A Reynolds; Erin D Giles; James W Grau
Journal:  Neurotrauma Rep       Date:  2022-01-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.