Literature DB >> 10601177

Noninvasive cardiac output measurement in orthostasis: pulse contour analysis compared with acetylene rebreathing.

W J Stok1, R C Stringer, J M Karemaker.   

Abstract

We tested the reliability of noninvasive cardiac output (CO) measurement in different body positions by pulse contour analysis (CO(pc)) by using a transmission line model (K. H. Wesseling, B. De Wit, J. A. P. Weber, and N. T. Smith. Adv. Cardiol. Phys. 5, Suppl. II: 16-52, 1983). Acetylene rebreathing (CO(rebr)) was used as a reference method. Twelve subjects (age 21-34 yr) were studied: 1) six in whom CO(rebr) and CO(pc) were measured in the standing and 6 degrees head-down tilt (HDT) postures and 2) six in whom CO was measured in the 30 degrees HDT, supine, 30 degrees head up-tilt (HUT), and 70 degrees HUT postures on a tilt table. The CO(rebr)-to-CO(pc) ratio in (near) the supine position during rebreathing was used as the calibration factor for CO(pc) measurements. Calibrated CO(pc) (CO(cal sup)) consistently overestimated CO in the upright posture. The drop in CO with upright posture was underestimated by approximately 50%. CO(cal sup) and CO(rebr) values did not differ in the 30 degrees HDT position. Changes in the CO(rebr)-to-CO(pc) ratio are highly variable among subjects in response to a change in posture. Therefore, CO(pc) must be recalibrated for each subject in each posture.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10601177     DOI: 10.1152/jappl.1999.87.6.2266

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  4 in total

1.  Haemodynamic adaptation during sudden gravity transitions.

Authors:  Jiexin Liu; Bart Verheyden; Frank Beckers; Andre E Aubert
Journal:  Eur J Appl Physiol       Date:  2011-04-11       Impact factor: 3.078

2.  Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound.

Authors:  Johannes J van Lieshout; Karin Toska; Erik Jan van Lieshout; Morten Eriksen; Lars Walløe; Karel H Wesseling
Journal:  Eur J Appl Physiol       Date:  2003-07-08       Impact factor: 3.078

3.  Effect of gastric distension on cardiovascular parameters: gastrovascular reflex is attenuated in the elderly.

Authors:  N P van Orshoven; P L Oey; L J van Schelven; J M M Roelofs; P A F Jansen; L M A Akkermans
Journal:  J Physiol       Date:  2004-01-14       Impact factor: 5.182

Review 4.  Noninvasive continuous hemodynamic monitoring.

Authors:  Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Journal:  J Clin Monit Comput       Date:  2012-06-14       Impact factor: 2.502

  4 in total