Literature DB >> 10599663

Randomized clinical trial of the 350-mm2 versus the 500-mm2 Baerveldt implant: longer term results: is bigger better?

M T Britt1, L D LaBree, M A Lloyd, D S Minckler, D K Heuer, G Baerveldt, R Varma.   

Abstract

OBJECTIVE: To report the longer term results of a randomized, clinical trial comparing the 350-mm2 and the 500-mm2 Baerveldt glaucoma implants.
DESIGN: Extended follow-up on a randomized, controlled trial. PARTICIPANTS: Between March 1991 and April 1993, 107 patients with uncontrolled intraocular pressure (IOP) due to non-neovascular glaucoma associated with aphakia, pseudophakia, or failed filters were randomly assigned for surgical placement of either the 350-mm or the 500-mm2 Baerveldt implant at the Doheny Eye Institute.
METHODS: A random-numbers table was used to assign each patient to one of the two groups. Preoperative IOPs and visual acuities were recorded. Clinical records were reviewed to ascertain postoperative IOPs, visual acuities, number of medications used, and implant-related complications that occurred throughout the follow-up period. MAIN OUTCOME MEASURES: Success was defined as IOP of 6 mmHg or greater and of 21 mmHg or less in two or more consecutive follow-up visits without further glaucoma surgery or loss of light perception attributable to glaucoma.
RESULTS: The overall success rates were 87% for the 350-mm2 group and 70% for the 500-mm2 group (P = 0.05). Average follow-up was 37 months (range, 1-76 months) for the 350-mm2 group and 34 months (range, 5-77 months) for the 500-mm2 group. The life-table success rates declined over time for both implant groups, from a high of 98% for the 350-mm2 group and 92% for the 500-mm2 group at 1 year to a cumulative success rate of 79% for the 350-mm2 group and 66% for the 500-mm2 group at 5 years. Visual acuities were better or remained the same in 50% of the patients in the 350-mm2 group and 46% of those in the 500-mm2 group. Complications during the 5-year follow-up were also statistically similar.
CONCLUSIONS: The longer term results show that the 350-mm2 Baerveldt implant is more successful than the 500-mm2 implant for overall IOP control. Interval comparisons indicate a higher rate of success for the 350-mm2 implant in the first, second, third, fourth, and fifth years of implantation. Visual acuities, implant-related complications, and average IOPs were statistically indistinguishable between the two groups.

Entities:  

Mesh:

Year:  1999        PMID: 10599663     DOI: 10.1016/S0161-6420(99)90532-8

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  34 in total

1.  Baerveldt implant in refractory glaucoma: long-term results and factors influencing outcome.

Authors:  S Roy; E Ravinet; A Mermoud
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  Trypan blue identifies antimetabolite treatment area in trabeculectomy.

Authors:  P R Healey; J G Crowston
Journal:  Br J Ophthalmol       Date:  2005-09       Impact factor: 4.638

3.  Modification of an adult-sized Ahmed glaucoma valve for a small globe.

Authors:  Ricky W K Law; Randa T H Li; Jimmy S M Lai; Srinivas K Rao; Dennis S C Lam
Journal:  Jpn J Ophthalmol       Date:  2006 Jan-Feb       Impact factor: 2.447

Review 4.  Aqueous shunts for glaucoma.

Authors:  D S Minckler; S S Vedula; T J Li; M C Mathew; R S Ayyala; B A Francis
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

5.  Baerveldt glaucoma implant in paediatric patients.

Authors:  K A van Overdam; J T H N de Faber; H G Lemij; P W T de Waard
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

6.  Five-year treatment outcomes in the Ahmed Baerveldt comparison study.

Authors:  Donald L Budenz; Keith Barton; Steven J Gedde; William J Feuer; Joyce Schiffman; Vital P Costa; David G Godfrey; Yvonne M Buys
Journal:  Ophthalmology       Date:  2014-10-17       Impact factor: 12.079

Review 7.  Aqueous shunts for glaucoma.

Authors:  Victoria L Tseng; Anne L Coleman; Melinda Y Chang; Joseph Caprioli
Journal:  Cochrane Database Syst Rev       Date:  2017-07-28

8.  Binocular disturbance after glaucoma drainage device implantation.

Authors:  Ta Chen Chang; Kara M Cavuoto
Journal:  World J Ophthalmol       Date:  2014-08-12

9.  Longer-term Baerveldt to Trabectome glaucoma surgery comparison using propensity score matching.

Authors:  Tigran Kostanyan; Tarek Shazly; Kevin B Kaplowitz; Steven Z Wang; Sushma Kola; Eric N Brown; Nils A Loewen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-09-25       Impact factor: 3.117

10.  A Retrospective Comparison of Primary Baerveldt Implantation versus Trabeculectomy with Mitomycin C.

Authors:  Joseph F Panarelli; Michael R Banitt; Steven J Gedde; Wei Shi; Joyce C Schiffman; William J Feuer
Journal:  Ophthalmology       Date:  2015-12-30       Impact factor: 12.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.