Pressure traps in femoro-popliteal reversed vein grafts. Are valves culprits?

F Robicsek1, M J Thubrikar, A Fokin, H F Tripp, B Fowler.   

Abstract

BACKGROUND: Stenosis is a major cause of vein graft failure in peripheral arterial surgery. Our goal is to determine whether vein valves play a role in this process by creating a "pressure trap".
METHODS: Seventeen patients with femoro-popliteal reversed saphenous vein grafts were studied intraoperatively. Flow and pressure in the grafts were measured, while the graft outflow was gradually occluded and released for 2-4 seconds. In 3 patients the graft flow was reduced by compressing calf muscles.
RESULTS: Patients heart rates were 54-84 BPM, blood pressures 170/80-110/55 mm Hg, and normal graft flow was 40-180 ml/min. In 12 patients with competent vein valves, at reduced flow (<30 m/min) the valves opened and closed in each cardiac cycle. At each closure the pressure was "trapped" distal to the valve producing diastolic hypertension. Also the flow was stagnant for a considerable portion of the cardiac cycle. Maximum diastolic pressure gradient across the valve ranged from 35 to 60 mm Hg and the level of pressure trapped was inversely proportional to the graft flow.
CONCLUSIONS: In patients in whom reversed vein grafts with competent valves are placed in the femoro-popliteal positions a "pressure-trap" develops in the distal segment. This segmental hypertension combined with the flow stagnation could play an important role in the graft thickening and stenosis.

Entities:  

Mesh:

Year:  1999        PMID: 10597003

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  1 in total

1.  Air vent of vein graft in extracranial-intracranial bypass surgery.

Authors:  Hirofumi Oyama; Akira Kito; Hideki Maki; Kenichi Hattori; Tomoyuki Noda; Kentaro Wada
Journal:  Nagoya J Med Sci       Date:  2012-08       Impact factor: 1.131

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.