Literature DB >> 10591469

On-line coupling of solid-phase extraction with mass spectrometry for the analysis of biological samples. I. Determination of clenbuterol in urine.

C H Bruins1, C M Jeronimus-Stratingh, K Ensing, W D van Dongen, G J de Jong.   

Abstract

The potential of the direct coupling of solid-phase extraction (SPE) with mass spectrometry (MS) for the analysis of biological samples is demonstrated. For SPE a cartridge exchanger is used and the eluate is directly introduced into the mass spectrometer. This system has been investigated for the determination of clenbuterol in urine. With mixed-mode cartridges, a considerable ion suppression has been obtained. The mass spectrum at the elution time of clenbuterol is dominated by that of creatinine and adduct formation of clenbuterol and creatinine has been observed. The whole procedure including injection of 1 ml urine, washing and desorption has been developed with cartridges containing 8-microm C18-bonded silica. If only a single MS step is used, the selectivity and, therefore, the sensitivity are insufficient. The detection limit is about 100 ng/ml. However, with atmospheric pressure chemical ionisation and the tandem MS mode the detection limit has been decreased to about 2 ng/ml and the ion suppression is only about 10%. For the electrospray ionisation the detection limit is about 10-times higher and the ion suppression is less favourable. The repeatability for the SPE-MS-MS procedure was 6.5% at 10 ng/ml (n=5) and the difference between the response factors at 10 ng/ml and 100 ng/ml was only 2.5%. The MS behaviour of clenbuterol and the matrix under the present conditions is discussed.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10591469     DOI: 10.1016/s0021-9673(99)00959-0

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  LC/MS analysis of stratum corneum lipids: ceramide profiling and discovery.

Authors:  Jeroen van Smeden; Louise Hoppel; Rob van der Heijden; Thomas Hankemeier; Rob J Vreeken; Joke A Bouwstra
Journal:  J Lipid Res       Date:  2011-03-28       Impact factor: 5.922

2.  Molecularly imprinted polymers as the extracted sorbents of clenbuterol ahead of liquid chromatographic determination.

Authors:  Sovichea Lay; Hai-Ning Yu; Bao-Xiang Hu; Sheng-Rong Shen
Journal:  J Zhejiang Univ Sci B       Date:  2016-06       Impact factor: 3.066

3.  Quantitative Measurement of Melittin in Asian Honeybee Venom Using a New Method Including UPLC-QqTOF-MS.

Authors:  Sheng Huang; Jianhua Wang; Zeqin Guo; Yan Wang; Chundong Liu
Journal:  Toxins (Basel)       Date:  2020-07-04       Impact factor: 4.546

Review 4.  Clinical Mass Spectrometry in the Bioinformatics Era: A Hitchhiker's Guide.

Authors:  Yeow-Kuan Chong; Chi-Chun Ho; Shui-Yee Leung; Susanna K P Lau; Patrick C Y Woo
Journal:  Comput Struct Biotechnol J       Date:  2018-08-28       Impact factor: 7.271

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.