Literature DB >> 10590498

New mapping technology for atrial tachycardias.

E Hoffmann1, P Nimmermann, C Reithmann, F Elser, T Remp, G Steinbeck.   

Abstract

UNLABELLED: Prerequisite for succesful radiofrequency catheter ablation of tachycardias is the exact mapping during the electrophysiological study. The new mapping system CARTO allows a three-dimensional color-coded electroanatomic map of impulse propagation using electromagnetic technology. The aim of this study was to determine the feasibility and safety of the new electromagnetic mapping technology CARTO for atrial tachycardias.
RESULTS: Electrophysiologic study and CARTO mapping was performed in 38 atrial tachycardias. The mapping procedure took 26 +/- 23 min. We created 33 maps within the right atrium and 5 maps within the left atrium with a mean of 74 +/- 38 different catheter positions. The mechanism was determined as reentrant in 9, junctional in 1 and focal in 28 tachycardias. In focal tachycardias the tachycardia cycle length (CL) and the total atrial activation time (AT) were clearly different (352 +/- 98 ms vs 99 +/- 25 ms). Reentrant tachycardias had a comparable CL and AT (236 +/- 44 ms vs 240 +/- 56 ms). In 83% of the focal tachycardias and in 67% of the reentrant tachycardias, ablation was performed successfully. No complications occured.
CONCLUSION: The electroanatomic mapping system allows high resolution visualization of electrical activity and may therefore improve precision and simplify the determination of the arrhythmogenic substrate during tachycardias for successful catheter ablation.

Entities:  

Mesh:

Year:  2000        PMID: 10590498     DOI: 10.1023/a:1009894903100

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  4 in total

1.  [Electro-anatomic mapping of the sinoatrial activation: initial experiences with the new CARTO mapping system].

Authors:  P Nimmermann; E Hoffmann; C Reithmann; T Remp; G Steinbeck
Journal:  Z Kardiol       Date:  1998-03

2.  A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results.

Authors:  L Gepstein; G Hayam; S A Ben-Haim
Journal:  Circulation       Date:  1997-03-18       Impact factor: 29.690

3.  Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms.

Authors:  M D Lesh; G F Van Hare; L M Epstein; A P Fitzpatrick; M M Scheinman; R J Lee; M A Kwasman; H R Grogin; J C Griffin
Journal:  Circulation       Date:  1994-03       Impact factor: 29.690

4.  Radiofrequency catheter ablation of atrial tachycardias.

Authors:  H Poty; N Saoudi; M Haissaguerre; A Daou; J Clementy; B Letac
Journal:  Am Heart J       Date:  1996-03       Impact factor: 4.749

  4 in total
  1 in total

1.  Benefits of new catheter mapping technology: fact or fiction?

Authors:  S Saksena
Journal:  J Interv Card Electrophysiol       Date:  2000-06       Impact factor: 1.900

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.