Literature DB >> 10589100

Strategies for locating disulfide bonds in a monoclonal antibody via mass spectrometry.

R Mhatre1, J Woodard, C Zeng.   

Abstract

The location of the disulfide bonds in a recombinant monoclonal antibody was confirmed by matrix-assisted laser desorption/ionization-time-of-flight (MALDI-TOF) and electrospray ionization (ESI) mass spectrometry (MS). A non-reduced Endoproteinase Lys-C (Endo Lys-C) digest of the antibody was analyzed directly by MALDI-TOFMS. The sample was then reduced on-plate by depositing dithiothreitol (DTT) on the sample spot and re-analyzed by MALDI-TOFMS. The disulfide bonds were assigned based on the disappearance of certain mass ions in the non-reduced digest and the appearance of product ions in the reduced digest. A rapid LC/ESI-MS protocol was also developed to determine the location of the disulfide bonds. The peptides generated from the Endo Lys-C digest of the antibody were partially separated on a high performance liquid chromatography (HPLC) column by utilizing a steep gradient and analyzed by ESI-MS. The masses of the partially resolved peptides were determined by deconvoluting the mass spectra. Copyright 1999 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10589100     DOI: 10.1002/(SICI)1097-0231(19991230)13:24<2503::AID-RCM818>3.0.CO;2-W

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  6 in total

Review 1.  Mass spectrometry innovations in drug discovery and development.

Authors:  D I Papac; Z Shahrokh
Journal:  Pharm Res       Date:  2001-02       Impact factor: 4.200

2.  Characterization and comparison of disulfide linkages and scrambling patterns in therapeutic monoclonal antibodies: using LC-MS with electron transfer dissociation.

Authors:  Yi Wang; Qiaozhen Lu; Shiaw-Lin Wu; Barry L Karger; William S Hancock
Journal:  Anal Chem       Date:  2011-03-23       Impact factor: 6.986

3.  Reversed-phase liquid chromatography in-line with negative ionization electrospray mass spectrometry for the characterization of the disulfide-linkages of an immunoglobulin gamma antibody.

Authors:  Dirk Chelius; Mary E Huff Wimer; Pavel V Bondarenko
Journal:  J Am Soc Mass Spectrom       Date:  2006-08-14       Impact factor: 3.109

4.  Optimizing the MALDI-TOF-MS observation of peptides containing disulfide bonds.

Authors:  Kristin G Huwiler; Deane F Mosher; Martha M Vestling
Journal:  J Biomol Tech       Date:  2003-12

5.  Differential labeling of free and disulfide-bound thiol functions in proteins.

Authors:  Bettina Seiwert; Heiko Hayen; Uwe Karst
Journal:  J Am Soc Mass Spectrom       Date:  2007-10-04       Impact factor: 3.109

Review 6.  Mass Spectrometry Approaches for Identification and Quantitation of Therapeutic Monoclonal Antibodies in the Clinical Laboratory.

Authors:  Paula M Ladwig; David R Barnidge; Maria A V Willrich
Journal:  Clin Vaccine Immunol       Date:  2017-05-05
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.