Evaluation of stabilized whole blood control materials for lymphocyte immunophenotyping.

J K Nicholson1, M Hubbard, C D Dawson.   

Abstract

We evaluated stabilized whole blood control materials for their performance as a routine control material for immunophenotyping using flow cytometry. These materials serve as the method control, controlling for both the binding of monoclonal antibodies to the cells and the efficiency of the red-blood-cell lysing reagent. Three products (FluoroTrol, StatusFlow, and CD-Chex): were tested. The controls performed very well in evaluating both CD4 and CD8 percentages and absolute cell counts using flow cytometry. Light scattering patterns and fluorescence intensity of antibody binding were slightly different from those of normal whole blood. These products are not appropriate for quantitative fluorescence standards. Cytometry (Comm. Clin. Cytometry) 38:268-273, 1999. Published 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  1999        PMID: 10589041     DOI: 10.1002/(sici)1097-0320(19991215)38:6<268::aid-cyto2>3.0.co;2-k

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  3 in total

1.  Quantification of cells with specific phenotypes I: determination of CD4+ cell count per microliter in reconstituted lyophilized human PBMC prelabeled with anti-CD4 FITC antibody.

Authors:  Richard Stebbings; Lili Wang; Janet Sutherland; Martin Kammel; Adolfas K Gaigalas; Manuela John; Bodo Roemer; Maren Kuhne; Rudolf J Schneider; Michael Braun; Andrea Engel; Dinesh K Dikshit; Fatima Abbasi; Gerald E Marti; Maria Paola Sassi; Laura Revel; Sook-Kyung Kim; Marc-Olivier Baradez; Tamara Lekishvili; Damian Marshall; Liam Whitby; Wang Jing; Volker Ost; Maxim Vonsky; Jörg Neukammer
Journal:  Cytometry A       Date:  2015-02-05       Impact factor: 4.355

2.  Compatibility of stabilized whole blood products with CD4 technologies and their suitability for quality assessment programs.

Authors:  Tao Ding; Michèle Bergeron; Peggy Seely; Xuefen Yang; Tamsir O Diallo; Margot Plews; Paul Sandstrom; T Blake Ball; Adrienne F A Meyers
Journal:  PLoS One       Date:  2014-08-08       Impact factor: 3.240

3.  Establishment and validation of in-house cryopreserved CAR/TCR-T cell flow cytometry quality control.

Authors:  Yihua Cai; Michaela Prochazkova; Chunjie Jiang; Hannah W Song; Jianjian Jin; Larry Moses; Nikolaos Gkitsas; Robert P Somerville; Steven L Highfill; Sandhya Panch; David F Stroncek; Ping Jin
Journal:  J Transl Med       Date:  2021-12-24       Impact factor: 5.531