Literature DB >> 10588630

Synchronization of radiograph film exposure with the inspiratory pause. Effect on the appearance of bedside chest radiographs in mechanically ventilated patients.

P B Langevin1, V Hellein, S M Harms, W K Tharp, C Cheung-Seekit, S Lampotang.   

Abstract

The appearance of portable chest radiographs (CXRs) may be affected by changes in ventilation, particularly when patients are mechanically ventilated. Synchronization of the CXR with the ventilatory cycle should limit the influence of respiratory variation on the appearance of the CXR. This study evaluates the effect of synchronizing the CXR film exposure with ventilation on the appearance of the radiograph. Twenty-five patients who remained intubated postoperatively, were mechanically ventilated, and required a CXR were enrolled in this triple-blind, randomized prospective study. Each patient received one radiograph using conventional techniques and another using the interface. The sequence of the two films was randomized, and the two films were taken on the same patient within a few minutes of each other. Hence, each patient served as his own control and the position of the patient, source-film distance, intensity (Kvp), and duration of the exposure (mAs) were identical for the two films. Five board-certified radiologists were then asked to compare paired films for clarity of lines and tubes, definition of the pulmonary vasculature, visibility of the mediastinum, definition of the diaphragm, and degree of lung inflation. Radiologists were also asked to choose which films they preferred. A majority of board certified radiologists preferred CXRs taken with the interface in 21 of 25 patients (p < 0.0001). Furthermore, four of the five criteria evaluated were improved (p < 0.05) on synchronized CXRs. Synchronization of the bedside CXR with the end of inspiration ensures that they are always obtained at maximal inflation, which improves the appearance of a majority of radiographs by at least one of five criteria.

Entities:  

Mesh:

Year:  1999        PMID: 10588630     DOI: 10.1164/ajrccm.160.6.9902060

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  3 in total

1.  The Importance of State and Context in Safe Interoperable Medical Systems.

Authors:  Sandy Weininger; Michael B Jaffe; Michael Robkin; Tracy Rausch; David Arney; Julian M Goldman
Journal:  IEEE J Transl Eng Health Med       Date:  2016-08-08       Impact factor: 3.316

2.  Vascular pedicle width in acute lung injury: correlation with intravascular pressures and ability to discriminate fluid status.

Authors:  Todd W Rice; Lorraine B Ware; Edward F Haponik; Caroline Chiles; Arthur P Wheeler; Gordon R Bernard; Jay S Steingrub; R Duncan Hite; Michael A Matthay; Patrick Wright; E Wesley Ely
Journal:  Crit Care       Date:  2011-03-07       Impact factor: 9.097

3.  Comparison of the Diagnostic and Therapeutic Efficacies of Portable Recruited Chest Radiography with Conventional Portable Radiography in Mechanically Ventilated Patients.

Authors:  Ali Sharifpour; Abdulrasool Alaee; Masoud Aliyali; Siavash Abedi; Neda Karimi
Journal:  Tanaffos       Date:  2019-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.