Impact of the ECG for detection of intraatrial conduction block after atrial flutter ablation.

C Weiss1, S Willems, M Hoffmann, T Meinertz.   

Abstract

Induction of complete bidirectional conduction block via the posterior isthmus of the right atrium is introduced as a standard endpoint for catheter ablation of atrial flutter. The present study sought to investigate the impact of changes in P wave duration and morphology detected by the surface ECG during coronary sinus and posterolateral right atrial stimulation as a marker for conduction block. Morphology and duration changes of the paced P wave before and after radiofrequency catheter (RFC) ablation were estimated in 22 patients referred for ablation of atrial flutter. We looked for a morphology change of the terminal portion in the 12-lead ECG and an increment of P wave duration. In 16 of 22 patients in whom atrial flutter ablation resulted in a complete bidirectional block, the conduction block was unidirectional in 4 patients and conduction times remained unchanged in 2 patients. After induction of complete bidirectional block a change of the terminal portion of the P wave towards a more positive morphology in one or more inferior leads was detected in 14 (88%) of 16 patients during coronary sinus stimulation and in 15 (94%) of 16 patients during posterolateral right atrial stimulation. These changes were predominantly observed in the inferior leads. Positive morphology changes of the terminal P wave portion in the inferior leads indicating conduction block with a sensitivity of 86% and a specificity of 100% were observed. An increment of 10 ms or more in P wave duration indicates conduction block with a specificity of 100% and a sensitivity of 67%. There was a significantly larger increment of P wave duration during coronary sinus (CS) stimulation compared to posterolateral right atrial stimulation (38 +/- 21 vs 16 +/- 21 ms). The analysis of P wave duration and morphology in the inferior leads of the surface ECG is a reliable tool to assess the intraatrial conduction after atrial flutter ablation. Different conduction during coronary sinus and posterolateral right atrial pacing may cause a different P wave duration after ablation.

Entities:  

Mesh:

Year:  1999        PMID: 10588147     DOI: 10.1111/j.1540-8159.1999.tb00349.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  1 in total

1.  A new and simple method for distinguishing complete from incomplete block through the cavotricuspid isthmus.

Authors:  Gabriel Laurent; Alexandra Bourcier; Géraldine Bertaux; Stéphane Fromentin; Michel Fraison; Stéphanie Gonzalez; François Saint Pierre; Jean Eric Wolf
Journal:  J Interv Card Electrophysiol       Date:  2006-01-18       Impact factor: 1.900

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.