Literature DB >> 10587911

Comparison of the quality of temporal subtraction images obtained with manual and automated methods of digital chest radiography.

S Katsuragawa1, H Tagashira, Q Li, H MacMahon, K Doi.   

Abstract

The authors have been developing a fully automated temporal subtraction scheme to assist radiologists in the detection of interval changes in digital chest radiographs. The temporal subtraction image is obtained by subtraction of a previous image from a current image. The authors' automated method includes not only image shift and rotation techniques but also a nonlinear geometric warping technique for reduction of misregistration artifacts in the subtraction image. However, a manual subtraction method that can be carried out only with image shift and rotation has been employed as a common clinical technique in angiography, and it might be clinically acceptable for detection of interval changes on chest radiographs as well. Therefore, the authors applied both the manual and automated temporal subtraction techniques to 181 digital chest radiographs, and compared the quality of the subtraction images obtained with the two methods. The numbers of clinically acceptable subtraction images were 147 (81.2%) and 176 (97.2%) for the manual and automated subtraction methods, respectively. The image quality of 148 (81.8%) subtraction images was improved by use of the automated method in comparison with the subtraction images obtained with the manual method. These results indicate that the automated method with the nonlinear warping technique can significantly reduce misregistration artifacts in comparison with the manual method. Therefore, the authors believe that the automated subtraction method is more useful for the detection of interval changes in digital chest radiographs.

Mesh:

Year:  1999        PMID: 10587911      PMCID: PMC3452422          DOI: 10.1007/BF03168852

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  9 in total

1.  Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change.

Authors:  T Ishida; S Katsuragawa; K Nakamura; H MacMahon; K Doi
Journal:  Med Phys       Date:  1999-07       Impact factor: 4.071

2.  Application of temporal subtraction for detection of interval changes on chest radiographs: improvement of subtraction images using automated initial image matching.

Authors:  T Ishida; K Ashizawa; R Engelmann; S Katsuragawa; H MacMahon; K Doi
Journal:  J Digit Imaging       Date:  1999-05       Impact factor: 4.056

3.  Image feature analysis for computer-aided diagnosis: accurate determination of ribcage boundary in chest radiographs.

Authors:  X W Xu; K Doi
Journal:  Med Phys       Date:  1995-05       Impact factor: 4.071

4.  Image feature analysis and computer-aided diagnosis in digital radiography: automated analysis of sizes of heart and lung in chest images.

Authors:  N Nakamori; K Doi; V Sabeti; H MacMahon
Journal:  Med Phys       Date:  1990 May-Jun       Impact factor: 4.071

5.  Digital chest radiography: effect of temporal subtraction images on detection accuracy.

Authors:  M C Difazio; H MacMahon; X W Xu; P Tsai; J Shiraishi; S G Armato; K Doi
Journal:  Radiology       Date:  1997-02       Impact factor: 11.105

6.  Computerized fluoroscopy in real time for noninvasive visualization of the cardiovascular system. Preliminary studies.

Authors:  R A Kruger; C A Mistretta; T L Houk; S J Riederer; C G Shaw; M M Goodsitt; A B Crummy; W Zwiebel; J C Lancaster; G G Rowe; D Flemming
Journal:  Radiology       Date:  1979-01       Impact factor: 11.105

7.  Digital image subtraction of temporally sequential chest images for detection of interval change.

Authors:  A Kano; K Doi; H MacMahon; D D Hassell; M L Giger
Journal:  Med Phys       Date:  1994-03       Impact factor: 4.071

8.  Computed radiography utilizing scanning laser stimulated luminescence.

Authors:  M Sonoda; M Takano; J Miyahara; H Kato
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

9.  Digital subtraction angiography of the abdominal aorta and renal arteries. Comparison with conventional aortography.

Authors:  E Buonocore; T F Meaney; G P Borkowski; W Pavlicek; J Gallagher
Journal:  Radiology       Date:  1981-05       Impact factor: 11.105

  9 in total
  7 in total

1.  Evaluation of the usefulness of color digital summation radiography in temporally sequential digital radiographs: a phantom study.

Authors:  Yuji Ogata; Hiroaki Naito; Noriyuki Tomiyama; Seiki Hamada; Takenori Kozuka; Mitsuhiro Koyama; Mitusko Tsubamoto; Sachiko Murai; Takashi Ueguchi; Mitsuhiro Matsumoto; Shinichi Tamura; Hironobu Nakamura; Takeshi Johkoh
Journal:  Radiat Med       Date:  2006-04

2.  Evaluation of the image quality of temporal subtraction images produced automatically in a PACS environment.

Authors:  Shuji Sakai; Hiroyasu Soeda; Akio Furuya; Hidetake Yabuuchi; Takashi Okafuji; Keiji Yamamoto; Hiroshi Honda; Kunio Doi
Journal:  J Digit Imaging       Date:  2006-12       Impact factor: 4.056

3.  Novel display technique for reference images for visibility of temporal change on radiographs--color digital summation radiography.

Authors:  Yuji Ogata; Hiroaki Naito; Hiroki Azuma; Hironari Toyota; Takashi Ueguchi; Mitsuhiro Matsumoto; Shinichi Tamura; s Hironobu Nakamura; Takeshi Johkoh
Journal:  Radiat Med       Date:  2006-01

4.  Evaluation of usefulness of color digital summation radiography for solitary pulmonary nodules on chest radiographs.

Authors:  Yuji Ogata; Hiroaki Naito; Noriyuki Tomiyama; Seiki Hamada; Mitusko Tsubamoto; Atsuo Inoue; Sachiko Murai; Hiromitu Sumikawa; Takashi Ueguchi; Mitsuhiro Matsumoto; Shinichi Tamura; Hiroyuki Nishinosono; Hironobu Nakamura; Takeshi Johkoh
Journal:  Radiat Med       Date:  2006-06

5.  Integration of temporal subtraction and nodule detection system for digital chest radiographs into picture archiving and communication system (PACS): four-year experience.

Authors:  Shuji Sakai; Hidetake Yabuuchi; Yoshio Matsuo; Takashi Okafuji; Takeshi Kamitani; Hiroshi Honda; Keiji Yamamoto; Keiichi Fujiwara; Naoki Sugiyama; Kunio Doi
Journal:  J Digit Imaging       Date:  2007-03-01       Impact factor: 4.056

6.  Development of a voxel-matching technique for substantial reduction of subtraction artifacts in temporal subtraction images obtained from thoracic MDCT.

Authors:  Yoshinori Itai; Hyoungseop Kim; Seiji Ishikawa; Shigehiko Katsuragawa; Kunio Doi
Journal:  J Digit Imaging       Date:  2008-11-20       Impact factor: 4.056

7.  Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system.

Authors:  Yasuo Sasaki; Katsumi Abe; Makiko Tabei; Shigehiko Katsuragawa; Atsuko Kurosaki; Shoji Matsuoka
Journal:  Radiol Phys Technol       Date:  2010-12-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.