Literature DB >> 10587616

Simulation of ion trajectories in a quadrupole ion trap: a comparison of three simulation programs

.   

Abstract

An attempt has been made to compare the performance, design and operation of three simulators, ISIS, ITSIM and SIMION-3D, when applied to the calculation of ion trajectories in a quadrupole ion trap. For the simulation of the trajectory of a single ion in a collision-free system, the calculated spatial trajectory components, kinetic energies and secular frequencies from the three simulators were virtually identical. It is concluded that, despite the various approaches to electrode design, calculation of fields, integration methods and ion generation tactics, there is a remarkable degree of consistency among the products of the simulators when dealing with collision-free conditions. The results of the ion injection simulations under collisional conditions were indicative of the complexity that can be introduced into the simulations with little effort. Random effects such as collisions of ions with He buffer gas and accumulated calculation errors together with the different collision model settings and the different approaches to field calculation are thought to have contributed to the somewhat minor differences in trapping efficiency. SIMION is the simulator of choice for the simulation of ion trajectories in hybrid instruments and in custom-designed assemblies of electrodes; and ITSIM would appear to be the best choice on the basis of computational speed for running multiparticle simulations and user friendliness. Both ISIS and ITSIM are adept at providing detailed information of collision events. Copyright 1999 John Wiley & Sons, Ltd.

Entities:  

Year:  1999        PMID: 10587616     DOI: 10.1002/(SICI)1096-9888(199912)34:12<1219::AID-JMS897>3.0.CO;2-L

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  5 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Computer Modeling of an Ion Trap Mass Analyzer, Part I: Low Pressure Regime.

Authors:  Dragan Nikolić; Stojan M Madzunkov; Murray R Darrach
Journal:  J Am Soc Mass Spectrom       Date:  2015-08-19       Impact factor: 3.109

3.  Ion trajectory simulation for electrode configurations with arbitrary geometries.

Authors:  Guangxiang Wu; R Graham Cooks; Zheng Ouyang; Meng Yu; William J Chappell; Wolfgang R Plass
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-21       Impact factor: 3.109

4.  Flowing gas in mass spectrometer: method for characterization and impact on ion processing.

Authors:  Xiaoyu Zhou; Zheng Ouyang
Journal:  Analyst       Date:  2014-08-14       Impact factor: 4.616

5.  Study of In-Trap Ion Clouds by Ion Trajectory Simulations.

Authors:  Xiaoyu Zhou; Xinwei Liu; Wenbo Cao; Xiao Wang; Ming Li; Haoxue Qiao; Zheng Ouyang