Literature DB >> 10587556

A preliminary study determining the feasibility of electromagnetic tracking for kinematics at the ankle joint complex.

J Woodburn1, D E Turner, P S Helliwell, S Barker.   

Abstract

OBJECTIVE: To determine the feasibility of using electromagnetic tracking (EMT) for quantifying three-dimensional kinematics at the ankle joint complex (AJC).
METHODS: AJC kinematics were recorded in 10 normal healthy adults, and 10 rheumatoid arthritis patients presenting with AJC instability and deformity who were undergoing footwear and orthotic intervention.
RESULTS: Kinematics in normal subjects had strong face validity, curve shape showing moderate (n=9), good (n=8) or excellent (n=4) agreement with data from seven published studies. The range of motion about the x-axis (15.2 degrees ) was similar to reference values (17.0 degrees ), but our technique underestimated rotations about the y- (8.1 degrees vs 14.0 degrees ) and z-axes (7.7 degrees vs 12.2 degrees ). In the rheumatoid arthritis pronated foot group, eversion and internal rotation during the stance phase of gait were between 2 and 5 times greater than for normal subjects. The use of a corrective foot orthosis in this group restored normal kinematics, reducing maximum eversion and internal rotation by 57 and 68%, respectively.
CONCLUSION: A new technique for measuring kinematics at the AJC is described. Based upon the findings of this pilot study, EMT may be useful for diagnosing AJC dysfunction and quantifying the mechanical efficacy of footwear and orthosis interventions.

Entities:  

Mesh:

Year:  1999        PMID: 10587556     DOI: 10.1093/rheumatology/38.12.1260

Source DB:  PubMed          Journal:  Rheumatology (Oxford)        ISSN: 1462-0324            Impact factor:   7.580


  4 in total

1.  A case-series study to explore the efficacy of foot orthoses in treating first metatarsophalangeal joint pain.

Authors:  Brian J Welsh; Anthony C Redmond; Nachiappan Chockalingam; Anne-Maree Keenan
Journal:  J Foot Ankle Res       Date:  2010-08-27       Impact factor: 2.303

Review 2.  Gait analysis using wearable sensors.

Authors:  Weijun Tao; Tao Liu; Rencheng Zheng; Hutian Feng
Journal:  Sensors (Basel)       Date:  2012-02-16       Impact factor: 3.576

3.  Reliability of two goniometric methods of measuring active inversion and eversion range of motion at the ankle.

Authors:  Collette Menadue; Jacqueline Raymond; Sharon L Kilbreath; Kathryn M Refshauge; Roger Adams
Journal:  BMC Musculoskelet Disord       Date:  2006-07-28       Impact factor: 2.362

Review 4.  Gait characteristics associated with the foot and ankle in inflammatory arthritis: a systematic review and meta-analysis.

Authors:  Matthew Carroll; Priya Parmar; Nicola Dalbeth; Mark Boocock; Keith Rome
Journal:  BMC Musculoskelet Disord       Date:  2015-06-05       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.