Spectra and air-kerma strength for encapsulated 192Ir sources.

J Borg1, D W Rogers.   

Abstract

The photon spectra in vacuum around four types of 192Ir HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on 192Ir decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare 192Ir source and around each of four types of encapsulated sources using recent mass energy-absorption coefficients. For the full spectrum the bare vs encapsulated difference is up to 23% due to the large air-kerma contribution from the unfiltered low-energy photons. For the penetrating part of the photon spectrum (> 11.3 keV), the air-kerma strength per unit source activity on the transverse axis for a bare source is 2-15% higher than for the encapsulated sources due to the attenuation and absorption in the core and the encapsulating material. The contribution to the air-kerma strength from photons scattered in the capsule and from bremsstrahlung are calculated to increase the air-kerma strength by 2-4% and 0.2-0.3%, respectively. Air-kerma strengths for a variety of sources agree well with previously reported results for sources from Nucletron International, Best Industries, Inc., and Alpha-Omega Services, Inc. In addition we present air-kerma strengths for the present model of the HDR source from Nucletron International and the source from Varian Associates, Inc.

Mesh:

Substances:

Year:  1999        PMID: 10587230     DOI: 10.1118/1.598763

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Air kerma strength characterization of a GZP6 Cobalt-60 brachytherapy source.

Authors:  Mohammad Taghi Bahreyni Toossi; Mahdi Ghorbani; Ali Asghar Mowlavi; Mojtaba Taheri; Mohsen Layegh; Yasha Makhdoumi; Ali Soleimani Meigooni
Journal:  Rep Pract Oncol Radiother       Date:  2010-11-09

2.  A Monte Carlo study on dose distribution evaluation of Flexisource (192)Ir brachytherapy source.

Authors:  Majid Alizadeh; Mahdi Ghorbani; Abbas Haghparast; Naser Zare; Toktam Ahmadi Moghaddas
Journal:  Rep Pract Oncol Radiother       Date:  2015-02-23

3.  An EGSnrc investigation of the air-kerma strength, dose rate constant, and radial dose function of 125I brachytherapy sources.

Authors:  Sridhar Sahoo; T Palani Selvam
Journal:  Radiol Phys Technol       Date:  2009-07-11

4.  Suitability of point kernel dose calculation techniques in brachytherapy treatment planning.

Authors:  Thilagam Lakshminarayanan; K V Subbaiah; K Thayalan; S E Kannan
Journal:  J Med Phys       Date:  2010-04

5.  A feasibility study of Fricke dosimetry as an absorbed dose to water standard for 192Ir HDR sources.

Authors:  Carlos Eduardo deAlmeida; Ricardo Ochoa; Marilene Coelho de Lima; Mariano Gazineu David; Evandro Jesus Pires; José Guilherme Peixoto; Camila Salata; Mario Antônio Bernal
Journal:  PLoS One       Date:  2014-12-18       Impact factor: 3.240

6.  The impact of uncertainties associated with MammoSite brachytherapy on the dose distribution in the breast.

Authors:  Saleh Bensaleh; Eva Bezak
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

7.  Evaluation of wall correction factor of INER's air-kerma primary standard chamber and dose variation by source displacement for HDR ¹⁹²Ir brachytherapy.

Authors:  J H Lee; J N Wang; T T Huang; S H Su; B J Chang; C H Su; S M Hsu
Journal:  Biomed Res Int       Date:  2013-10-08       Impact factor: 3.411

8.  Thin-film CdTe detector for microdosimetric study of radiation dose enhancement at gold-tissue interface.

Authors:  Nava Raj Paudel; Diana Shvydka; E Ishmael Parsai
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.