Literature DB >> 10587212

Estimation of the depth-dependent component of the point spread function of SPECT.

F J Beekman1, E T Slijpen, H W de Jong, M A Viergever.   

Abstract

The point spread function (PSF) of a gamma camera describes the photon count density distribution at the detector surface when a point source is imaged. Knowledge of the PSF is important for computer simulation and accurate image reconstruction of single photon emission computed tomography (SPECT) images. To reduce the number of measurements required for PSF characterization and the amount of computer memory to store PSF tables, and to enable generalization of the PSF to different collimator-to-source distances, the PSF may be modeled as the two-dimensional (2D) convolution of the depth-dependent component which is free of detector blurring (PSF(ideal)) and the distance-dependent detector response. Owing to limitations imposed by the radioactive strength of point sources, extended sources have to be used for measurements. Therefore, if PSF(ideal) is estimated from measured responses, corrections have to be made for both the detector blurring and for the extent of the source. In this paper, an approach based on maximum likelihood expectation-maximization (ML-EM) is used to estimate PSF(ideal). In addition, a practical measurement procedure which avoids problems associated with commonly used line-source measurements is proposed. To decrease noise and to prevent nonphysical solutions, shape constraints are applied during the estimation of PSF(ideal). The estimates are generalized to depths other than those which have been measured and are incorporated in a SPECT simulator. The method is validated for Tc-99m and T1-201 by means of measurements on physical phantoms. The corrected responses have the desired shapes and simulated responses closely resemble measured responses. The proposed methodology may, consequently, serve as a basis for accurate three-dimensional (3D) SPECT reconstruction.

Mesh:

Substances:

Year:  1999        PMID: 10587212     DOI: 10.1118/1.598745

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Iterative reconstruction of Fourier-rebinned PET data using sinogram blurring function estimated from point source scans.

Authors:  Michel S Tohme; Jinyi Qi
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

Review 2.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

3.  Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurements.

Authors:  Michel S Tohme; Jinyi Qi
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

4.  A systematic optimization of 19F MR image acquisition to detect macrophage invasion into an ECM hydrogel implanted in the stroke-damaged brain.

Authors:  Harmanvir Ghuman; T Kevin Hitchens; Michel Modo
Journal:  Neuroimage       Date:  2019-08-10       Impact factor: 6.556

5.  High fidelity system modeling for high quality image reconstruction in clinical CT.

Authors:  Synho Do; William Clem Karl; Sarabjeet Singh; Mannudeep Kalra; Tom Brady; Ellie Shin; Homer Pien
Journal:  PLoS One       Date:  2014-11-12       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.