| Literature DB >> 10582374 |
G L Hortin1, S K Dey, M Hall, C A Robinson.
Abstract
Azide salts are highly toxic compounds that have been difficult to detect in forensic samples. Here, anion analysis by capillary electrophoresis with indirect spectrophotometric detection was applied to detect azide in forensic specimens from two suicide victims. Gastric specimens from the victims were shown to have high azide concentrations; azide represented one of the major anionic components and no corresponding component occurred in normal gastric juice. Samples of blood and bile had low concentrations of azide near the limits of detection. The method described for azide analysis used simple steps for sample preparation and analysis time was less than 10 min per sample. It offers a simple and reliable method for detecting azide in biological fluids.Entities:
Mesh:
Substances:
Year: 1999 PMID: 10582374
Source DB: PubMed Journal: J Forensic Sci ISSN: 0022-1198 Impact factor: 1.832