OBJECTIVE: To characterize the pharmacokinetic profile of the somatostatin analog lanreotide in patients with severe chronic renal insufficiency. METHODS: Lanreotide was administered by intravenous bolus (7 microg/kg) to 12 patients with severe chronic renal insufficiency and to 12 healthy subjects. Lanreotide serum levels were determined by a radioimmunoassay procedure from time 0 until 24 hours after the administration. The main pharmacokinetic parameters were estimated by a noncompartmental treatment of data. RESULTS: The total serum clearance of lanreotide was found to be significantly lower in patients with severe chronic renal insufficiency than in healthy subjects (mean +/- SEM values of 0.138 +/- 0.017 L/hr/kg versus 0.244 +/- 0.027 L/hr/kg; P < .005). The initial lanreotide concentration, the elimination half-life, the area under the curve from time zero to 24 hours, and the area under the curve from time zero to infinity were significantly greater in patients with severe chronic renal insufficiency than in healthy subjects (307.45 +/- 79.19 ng/mL versus 127.18 +/- 22.65 ng/mL [P < .05]; 2.39 +/- 0.33 hours versus 1.32 +/- 0.20 hours [P < .005]; 62.55 +/- 9.73 ng/mL x hr versus 32.09 +/- 3.23 ng/mL x hr [P < .005]; and 62.95 +/- 9.78 ng/mL x hr versus 32.30 +/- 3.23 ng/mL x hr [P < .005], respectively). The initial volume of distribution, but not the volume of distribution at steady state, was significantly lower in patients with severe chronic renal insufficiency (0.040 +/- 0.008 L/kg versus 0.092 +/- 0.020 L/kg [P < .05] and 0.110 +/- 0.018 L/kg versus 0.172 +/- 0.046 L/kg [difference not statistically significant], respectively). The mean residence time was similar in both groups (0.77 +/- 0.06 hours versus 0.65 +/- 0.14 hours [difference not statistically significant]). CONCLUSIONS: A reduction in the total serum clearance and a decrease in the initial volume of distribution of lanreotide were observed in patients with severe chronic renal insufficiency treated with one intravenous bolus dose of 7 microg/kg lanreotide.
OBJECTIVE: To characterize the pharmacokinetic profile of the somatostatin analog lanreotide in patients with severe chronic renal insufficiency. METHODS: Lanreotide was administered by intravenous bolus (7 microg/kg) to 12 patients with severe chronic renal insufficiency and to 12 healthy subjects. Lanreotide serum levels were determined by a radioimmunoassay procedure from time 0 until 24 hours after the administration. The main pharmacokinetic parameters were estimated by a noncompartmental treatment of data. RESULTS: The total serum clearance of lanreotide was found to be significantly lower in patients with severe chronic renal insufficiency than in healthy subjects (mean +/- SEM values of 0.138 +/- 0.017 L/hr/kg versus 0.244 +/- 0.027 L/hr/kg; P < .005). The initial lanreotide concentration, the elimination half-life, the area under the curve from time zero to 24 hours, and the area under the curve from time zero to infinity were significantly greater in patients with severe chronic renal insufficiency than in healthy subjects (307.45 +/- 79.19 ng/mL versus 127.18 +/- 22.65 ng/mL [P < .05]; 2.39 +/- 0.33 hours versus 1.32 +/- 0.20 hours [P < .005]; 62.55 +/- 9.73 ng/mL x hr versus 32.09 +/- 3.23 ng/mL x hr [P < .005]; and 62.95 +/- 9.78 ng/mL x hr versus 32.30 +/- 3.23 ng/mL x hr [P < .005], respectively). The initial volume of distribution, but not the volume of distribution at steady state, was significantly lower in patients with severe chronic renal insufficiency (0.040 +/- 0.008 L/kg versus 0.092 +/- 0.020 L/kg [P < .05] and 0.110 +/- 0.018 L/kg versus 0.172 +/- 0.046 L/kg [difference not statistically significant], respectively). The mean residence time was similar in both groups (0.77 +/- 0.06 hours versus 0.65 +/- 0.14 hours [difference not statistically significant]). CONCLUSIONS: A reduction in the total serum clearance and a decrease in the initial volume of distribution of lanreotide were observed in patients with severe chronic renal insufficiency treated with one intravenous bolus dose of 7 microg/kg lanreotide.
Authors: Brian Tomlinson; Neil G Thomas; Irene W Lan; Manuel Barbanoj; Rosa M Antonijoan; Eva Drazna; Joaquim Ramis; Rosendo Obach; Concepción Peraire Journal: Clin Pharmacokinet Date: 2006 Impact factor: 6.447
Authors: Brian M Zeglis; Jacob L Houghton; Michael J Evans; Nerissa Viola-Villegas; Jason S Lewis Journal: Inorg Chem Date: 2013-12-06 Impact factor: 5.165
Authors: Núria Buil-Bruna; María Jesús Garrido; Marion Dehez; Amandine Manon; Thi Xuan Quyen Nguyen; Edda L Gomez-Panzani; Iñaki F Trocóniz Journal: Clin Pharmacokinet Date: 2016-04 Impact factor: 6.447
Authors: Esther Meijer; Joost P H Drenth; Hedwig d'Agnolo; Niek F Casteleijn; Johan W de Fijter; Tom J Gevers; Peter Kappert; Dorien J M Peters; Mahdi Salih; Darius Soonawala; Edwin M Spithoven; Vicente E Torres; Folkert W Visser; Jack F M Wetzels; Robert Zietse; Ron T Gansevoort Journal: Am J Kidney Dis Date: 2013-12-15 Impact factor: 8.860
Authors: Marta Martín-Richard; Bartomeu Massutí; Eva Pineda; Vicente Alonso; Maribel Marmol; Daniel Castellano; Emilio Fonseca; Antonio Galán; Marta Llanos; Maria Angeles Sala; Carlos Pericay; Fernando Rivera; Javier Sastre; Angel Segura; Maria Quindós; Pascal Maisonobe Journal: BMC Cancer Date: 2013-09-20 Impact factor: 4.430