Literature DB >> 10577592

Wrapping hydroxyapatite orbital implants with posterior auricular muscle complex grafts.

T C Naugle1, A M Lee, B G Haik, M A Callahan.   

Abstract

PURPOSE: To report the use of posterior auricular muscle complex grafts as a wrapping material for hydroxyapatite orbital implants in enucleation surgery.
METHOD: In a retrospective multicenter study, autogenous posterior auricular muscle complex grafts were used to cover hydroxyapatite orbital implants in 83 patients with a mean age of 38.6 years (range, 1 to 85 years), of whom 63 had primary unilateral enucleation and 20 had secondary orbital implants following enucleation. The mean follow-up period after posterior auricular muscle complex grafts was 36 months (range, 14 to 60 months).
RESULTS: Of the 83 patients, two (2.4%) developed limited orbital implant exposure, which was treated with a second posterior auricular muscle complex "patch graft." No patient developed postoperative orbital infection or implant extrusion. All patients were fitted with an acceptable prosthesis and had satisfactory cosmetic and functional results. No patient developed vascular compromise or a wound defect associated with the posterior auricular donor site.
CONCLUSION: Autogenous posterior auricular muscle complex grafts should be considered as an appropriate wrapping material for hydroxyapatite orbital implants for primary enucleation and for secondary orbital implants after enucleation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10577592     DOI: 10.1016/s0002-9394(99)00159-2

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  4 in total

1.  Bovine pericardium (Ocuguard) wrap for hydroxyapatite implants.

Authors:  M Gupta; A D Singh; P A Rundle; I G Rennie
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

2.  Use of bovine pericardium as a wrapping material for hydroxyapatite orbital implants.

Authors:  M Gupta; P Puri; I G Rennie
Journal:  Br J Ophthalmol       Date:  2002-03       Impact factor: 4.638

3.  High density porous polyethylene material (Medpor) as an unwrapped orbital implant.

Authors:  Yan-hong Chen; Hong-guang Cui
Journal:  J Zhejiang Univ Sci B       Date:  2006-08       Impact factor: 3.066

4.  Use of extraocular muscle flaps in the correction of orbital implant exposure.

Authors:  Hsueh-Yen Chu; Yi-Lin Liao; Yueh-Ju Tsai; Yen-Chang Chu; Shu-Ya Wu; Lih Ma
Journal:  PLoS One       Date:  2013-09-25       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.