Literature DB >> 10576710

Magnetic resonance cholangiopancreatography: comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences.

N Papanikolaou1, A H Karantanas, E Heracleous, J C Costa, N Gourtsoyiannis.   

Abstract

The purpose of this study was to compare the relative conspicuity of the pancreaticobiliary tree on respiratory-triggered three-dimensional turbo spin echo (3D TSE RT) and breath hold single-shot turbo spin echo (SSTSE BH) acquisitions respectively in MRCP imaging. Both techniques were applied to 61 patients with clinically suspected pancreaticobiliary disease using a 1.0 T MR system. All images were reviewed blindly. Qualitative comparison was made by grading subjectively the conspicuity of extrahepatic, intrahepatic, and main pancreatic ducts. Quantitative comparison included calculations of signal-to-noise ratio of the common bile duct, main pancreatic duct, gallbladder, liver, and contrast-to-noise ratio, relative contrast between common bile duct, gallbladder, and liver. 3D TSE RT provided significantly higher signal-to-noise ratio of the common bile duct (mean value 163.19) and main pancreatic duct (mean value 95.37) compared to SSTSE BH (mean values 76.24 and 26.22, respectively). 3D TSE RT was inferior to SSTSE BH for the depiction of intrahepatic ducts and pancreatic duct (head portion). 3D TSE RT and SSTSE BH sequences provide complimentary information in the visualization of the biliary and pancreatic ducts. Further comparative clinical studies are needed to redefine the sensitivity, specificity, and accuracy of MRCP using both sequences.

Entities:  

Mesh:

Year:  1999        PMID: 10576710     DOI: 10.1016/s0730-725x(99)00074-0

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  MR signal changes on hepatobiliary imaging after oral ingestion of manganese chloride tetrahydrate: preliminary examination.

Authors:  Nagaaki Marugami; Megumi Takewa; Yoshinori Iwaki; Yutaka Hazeyama; Kazumi Iwato; Junko Takahama; Aki Marugami; Tomoyuki Okuaki; Kimihiko Kichikawa
Journal:  Jpn J Radiol       Date:  2013-09-26       Impact factor: 2.374

2.  Three-dimensional visualization technique compared with magnetic resonance cholangiopancreatography for evaluation of anatomic variants of pediatric congenital choledochal cysts.

Authors:  Yiming Gong; Peng Wang; Shijiao Lu; Jie Chen
Journal:  Pediatr Surg Int       Date:  2021-01-28       Impact factor: 1.827

3.  Magnetic resonance cholangiopancreatography: Comparison of two- and three-dimensional sequences for the assessment of pancreatic cystic lesions.

Authors:  Kefu Liu; Ping Xie; Weijun Peng; Zhengrong Zhou
Journal:  Oncol Lett       Date:  2015-02-05       Impact factor: 2.967

4.  3D-MRCP for evaluation of intra- and extrahepatic bile ducts: comparison of different acquisition and reconstruction planes.

Authors:  Kristina Imeen Ringe; Dagmar Hartung; Christian von Falck; Frank Wacker; Hans-Jürgen Raatschen
Journal:  BMC Med Imaging       Date:  2014-05-19       Impact factor: 1.930