S Zhou1, J W Paxton, M D Tingle, J McCall, P Kestell.
Abstract
High-performance liquid chromatographic methods have been developed and validated for the glucuronidated and oxidative metabolites of the novel anti-tumour agent 5,6-dimethylxanthenone-4-acetic acid (DMXAA), produced in human liver microsomal incubations. Calibration curves for DMXAA acyl glucuronide (DMXAA-Glu) and 6-hydroxymethyl-5-methylxanthenone-4-acetic acid (6-OH-MXAA) were constructed over the concentration ranges of 0.25 to 20 and 0.5 to 40 microM, respectively. Assay performance was determined by intra- and inter-day accuracy and precision of quality control (QC) samples. The difference between the theoretical and measured concentration, and the coefficient of variation, were less than 15% at low QC concentrations, and less than 10% at medium and high QC concentrations for both analytes. The methods presented good accuracy, precision and sensitivity for use in kinetic studies of the glucuronidated and oxidative metabolites of DMXAA in human liver microsomes.Entities:
Mesh:
Substances:
Year: 1999 PMID: 10574198 DOI: 10.1016/s0378-4347(99)00341-2
Source DB: PubMed Journal: J Chromatogr B Biomed Sci Appl ISSN: 1387-2273