Dental unit waterlines: approaching the year 2000. ADA Council on Scientific Affairs.

.   

Abstract

BACKGROUND: This article discusses biofilm formation in dental unit waterlines and its resulting potential health effects. It also provides a review of ongoing research and available means to reduce microbial contamination in dental unit water.
METHODS: An expert panel was convened by the American Dental Association Board of Trustees to discuss the implications of biofilms in dentistry. This report summarizes the panel's conclusions.
CONCLUSIONS: The dental profession must continue its awareness of the presence of high levels of opportunistic microorganisms in dental unit water. Despite the lack of evidence of adverse health effects related to these microorganisms, they have the potential to overload the defense systems of immunocompromised patients and occupationally exposed dental staff members. Steps should be taken to improve dental unit water quality; contact of a patient's open wound, mucous membrane or body cavity with water of poor microbiological quality simply is inconsistent with patient expectations of modern dentistry. Efforts should continue to evaluate the health implications of biofilms in dentistry as new technology, research and data become available.

Entities:  

Mesh:

Year:  1999        PMID: 10573949

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  12 in total

1.  Comparison of the microbial load of incoming and distal outlet waters from dental unit water systems in Istanbul.

Authors:  Irfan Türetgen; Duygu Göksay; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2008-10-09       Impact factor: 2.513

2.  Rechargeable biofilm-controlling tubing materials for use in dental unit water lines.

Authors:  Jie Luo; Nuala Porteous; Yuyu Sun
Journal:  ACS Appl Mater Interfaces       Date:  2011-07-01       Impact factor: 9.229

3.  Effect of biocides on biofilm bacteria from dental unit water lines.

Authors:  I Liaqat; A N Sabri
Journal:  Curr Microbiol       Date:  2008-03-06       Impact factor: 2.188

4.  Evaluation of effect of three different dental unit waterline antimicrobials on the shear bond strength to dentin - An ex vivo study.

Authors:  Bv Sreenivasa Murthy; Kv Manjula; John V George; N Shruthi
Journal:  J Conserv Dent       Date:  2012-07

5.  Evaluation of gram negative bacterial contamination in dental unit water supplies in a university clinic in tabriz, iran.

Authors:  Firoz Pouralibaba; Esrafil Balaei; Atabak Kashefimehr
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-09-05

Review 6.  Prions and dentistry.

Authors:  Stephen R Porter
Journal:  J R Soc Med       Date:  2002-04       Impact factor: 18.000

7.  Effects of hydrogen peroxide on dental unit biofilms and treatment water contamination.

Authors:  Shih-Ming Lin; Kathy K H Svoboda; Anthony Giletto; Jeff Seibert; Raghunath Puttaiah
Journal:  Eur J Dent       Date:  2011-01

8.  Isolation of Pseudomonas aeruginosa strains from dental office environments and units in Barretos, state of São Paulo, Brazil, and analysis of their susceptibility to antimicrobial drugs.

Authors:  Ana Claudia de Oliveira; Renato Pariz Maluta; Ariel Eurides Stella; Everlon Cid Rigobelo; José Moacir Marin; Fernando Antonio de Ávila
Journal:  Braz J Microbiol       Date:  2008-09-01       Impact factor: 2.476

9.  Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines.

Authors:  Raha Habib Agahi; Maryam Alsadat Hashemipour; Mahsa Kalantari; Amin Ayatollah-Mosavi; Hossein Aghassi; Amir Hossein Gandjalikhan Nassab
Journal:  Dent Res J (Isfahan)       Date:  2014-05

10.  Substantivity of hypochlorous acid-based disinfectant against biofilm formation in the dental unit waterlines.

Authors:  Irfana Fathima Shajahan; Deivanayagam Kandaswamy; L Lakshminarayanan; R Selvarajan
Journal:  J Conserv Dent       Date:  2017 Jan-Feb
View more