Literature DB >> 10571931

Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: comparison with hyperbolic secant.

M N Yongbi1, Y Yang, J A Frank, J H Duyn.   

Abstract

Perfusion studies based on pulsed arterial spin labeling have primarily applied hyperbolic secant (HS) pulses for spin inversion. To optimize perfusion sensitivity, it is highly desirable to implement the HS pulse with the same slice width as the width of the imaging pulse. Unfortunately, this approach causes interactions between the slice profiles and manifests as residual signal from static tissue in the resultant perfusion image. This problem is currently overcome by increasing the selective HS width relative to the imaging slice width. However, this solution increases the time for the labeled blood to reach the imaging slice (transit time), causing loss of perfusion sensitivity as a result of T(1) relaxation effects. In this study, we demonstrate that the preceding problems can be largely overcome by use of the C-shaped frequency offset corrected inversion (FOCI) pulse [Ordidge et al., Magn Reson Med 1996;36:562]. The implementation of this pulse for multislice perfusion imaging on the cerebrum is presented, showing substantial improvement in slice definition in vivo compared with the HS pulse. The sharper FOCI profile is shown to reduce the physical gap (or "safety margin") between the inversion and imaging slabs, resulting in a significant increase in perfusion signal without residual contamination from static tissue. The mean +/- SE (n = 6) gray matter perfusion-weighted signal (DeltaM/M(o)) without the application of vascular signal suppression gradients were 1.19 +/- 0. 10% (HS-flow-sensitive alternating inversion recovery [FAIR]), and 1. 51 +/- 0.11% for the FOCI-FAIR sequence. The corresponding values with vascular signal suppression were 0.64 +/- 0.14%, and 0.91 +/- 0. 08% using the HS- and FOCI-FAIR sequences, respectively. Compared with the HS-based data, the FOCI-FAIR results correspond to an average increase in perfusion signal of up to between 26%-30%. Magn Reson Med 42:1098-1105, 1999. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10571931     DOI: 10.1002/(sici)1522-2594(199912)42:6<1098::aid-mrm14>3.0.co;2-1

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Confounding effect of large vessels on MR perfusion images analyzed with independent component analysis.

Authors:  Timothy J Carroll; Victor M Haughton; Howard A Rowley; Dietmar Cordes
Journal:  AJNR Am J Neuroradiol       Date:  2002 Jun-Jul       Impact factor: 3.825

2.  Distinct patterns of brain activity evoked by histamine-induced itch reveal an association with itch intensity and disease severity in atopic dermatitis.

Authors:  Y Ishiuji; R C Coghill; T S Patel; Y Oshiro; R A Kraft; G Yosipovitch
Journal:  Br J Dermatol       Date:  2009-05-15       Impact factor: 9.302

3.  Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging.

Authors:  Weiying Dai; Philip M Robson; Ajit Shankaranarayanan; David C Alsop
Journal:  Magn Reson Med       Date:  2011-11-14       Impact factor: 4.668

4.  Steady pulsed imaging and labeling scheme for noninvasive perfusion imaging.

Authors:  Jiadi Xu; Qin Qin; Dan Wu; Jun Hua; Xiaolei Song; Michael T McMahon; Frances J Northington; Jiangyang Zhang; Peter C M van Zijl; James J Pekar
Journal:  Magn Reson Med       Date:  2015-03-02       Impact factor: 4.668

5.  Anesthetic effects on regional CBF, BOLD, and the coupling between task-induced changes in CBF and BOLD: an fMRI study in normal human subjects.

Authors:  Maolin Qiu; Ramachandran Ramani; Michael Swetye; Nallakkandi Rajeevan; R Todd Constable
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

6.  Arterial transit time effects in pulsed arterial spin labeling CBF mapping: insight from a PET and MR study in normal human subjects.

Authors:  Maolin Qiu; R Paul Maguire; Jagriti Arora; Beata Planeta-Wilson; David Weinzimmer; Jinghua Wang; Yuenan Wang; Hyeonjin Kim; Nallakkandi Rajeevan; Yiyun Huang; Richard E Carson; R Todd Constable
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

Review 7.  Arterial spin-labeled MR perfusion imaging: clinical applications.

Authors:  Jeffrey M Pollock; Huan Tan; Robert A Kraft; Christopher T Whitlow; Jonathan H Burdette; Joseph A Maldjian
Journal:  Magn Reson Imaging Clin N Am       Date:  2009-05       Impact factor: 2.266

8.  The effect of daily caffeine use on cerebral blood flow: How much caffeine can we tolerate?

Authors:  Merideth A Addicott; Lucie L Yang; Ann M Peiffer; Luke R Burnett; Jonathan H Burdette; Michael Y Chen; Satoru Hayasaka; Robert A Kraft; Joseph A Maldjian; Paul J Laurienti
Journal:  Hum Brain Mapp       Date:  2009-10       Impact factor: 5.038

9.  Spatial nonuniformity of the resting CBF and BOLD responses to sevoflurane: in vivo study of normal human subjects with magnetic resonance imaging.

Authors:  Maolin Qiu; Ramachandran Ramani; Michael Swetye; Robert Todd Constable
Journal:  Hum Brain Mapp       Date:  2008-12       Impact factor: 5.038

10.  Does arterial spin-labeling MR imaging-measured tumor perfusion correlate with renal cell cancer response to antiangiogenic therapy in a mouse model?

Authors:  Rachel Schor-Bardach; David C Alsop; Ivan Pedrosa; Stephanie A Solazzo; Xiaoen Wang; Robert P Marquis; Michael B Atkins; Meredith Regan; Sabina Signoretti; Robert E Lenkinski; S Nahum Goldberg
Journal:  Radiology       Date:  2009-06       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.