Literature DB >> 10571905

Striated muscle microvascular response to silver implants: A comparative in vivo study with titanium and stainless steel.

C N Kraft1, M Hansis, S Arens, M D Menger, B Vollmar.   

Abstract

Local microvascular perfusion is the primary line of defense of tissue against microorganisms and plays a considerable role in reparative processes. The impairment of the microcirculation by a biomaterial may therefore have profound consequences. Silver is known to have excellent antimicrobial activity and, although regional and systemic toxic effects have been described, silver is regularly discussed as an implant material in bone surgery. Because little is known about the influence of silver implants on the adjacent host tissue microvasculature, we studied in vivo nutritive perfusion and leukocytic response, and compared these results with those of the conventionally used materials titanium and stainless steel. Using the hamster dorsal skinfold chamber preparation and intravital microscopy, the implantation of a commercially pure silver sample led to a distinct and persistent activation of leukocytes combined with a marked disruption of the microvascular endothelial integrity, massive leukocyte extravasation, and considerable venular dilation. Whereas animals with stainless-steel implants showed a moderate increase in these parameters with a tendency to recuperate, titanium implants caused only a transient increase of leukocyte-endothelial cell interaction within the first 120 min and no significant change in macromolecular leakage, leukocyte extravasation and venular diameter. After 3 days, five of six preparations with silver samples showed severe inflammation and massive edema. Thus, the use of silver as an implant material should be critically judged despite its bactericidal properties. The implant material titanium seems to be well tolerated by the local vascular system and currently represents the golden standard. Copyright 2000 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10571905     DOI: 10.1002/(sici)1097-4636(200002)49:2<192::aid-jbm6>3.0.co;2-c

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  15 in total

1.  Antimicrobial efficacy of a silver-zeolite matrix coating on stainless steel.

Authors:  Marjorie M Cowan; Kelly Z Abshire; Stephanie L Houk; Suzanne M Evans
Journal:  J Ind Microbiol Biotechnol       Date:  2003-01-14       Impact factor: 3.346

2.  A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat.

Authors:  Stephen P Chelko; Chad W Schmiedt; Tristan H Lewis; Stephen J Lewis; Tom P Robertson
Journal:  J Appl Physiol (1985)       Date:  2011-11-10

3.  Implications of orthopedic fretting corrosion particles on skeletal muscle microcirculation.

Authors:  C N Kraft; B Burian; O Diedrich; M A Wimmer
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

4.  Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to well-established titanium alloys.

Authors:  Peter H Pennekamp; Markus A Wimmer; Lukas Eschbach; Björn Burian; Peter Koch; Clayton N Kraft
Journal:  J Mater Sci Mater Med       Date:  2007-06-09       Impact factor: 3.896

5.  New TiAg composite coating for bone prosthesis engineering shows promising microvascular compatibility in the murine dorsal skinfold chamber model.

Authors:  Ann-Kathrin Behrendt; Maximilian Beythien; Jakob Huber; Thorsten Zufraß; Antje Butschkau; Thomas Mittlmeier; Brigitte Vollmar
Journal:  J Mater Sci Mater Med       Date:  2015-01-15       Impact factor: 3.896

6.  Inhibition of biofilm formation on iodine-supported titanium implants.

Authors:  Daisuke Inoue; Tamon Kabata; Kaori Ohtani; Yoshitomo Kajino; Toshiharu Shirai; Hiroyuki Tsuchiya
Journal:  Int Orthop       Date:  2017-04-07       Impact factor: 3.075

7.  Prolene-Monocryl-composite meshes do not increase microvascular Staphylococcus aureus adherence and do not sensitize for leukocytic inflammation.

Authors:  Jonas Roller; Matthias W Laschke; Shneh Sethi; Mathias Herrmann; Michael D Menger
Journal:  Langenbecks Arch Surg       Date:  2008-03-06       Impact factor: 3.445

8.  Vascular smooth muscle contraction/relaxation of rat carotid artery is not altered by bone grafting substitutes in vitro.

Authors:  Ahmet Atila Ertan; Nilufer Celebi Beriat; Aylin Gürpinar; Mehmet Ali Onur; Murat Cavit Cehreli
Journal:  Oral Maxillofac Surg       Date:  2010-06

9.  Innovative antimicrobial coating of titanium implants with iodine.

Authors:  Hiroyuki Tsuchiya; Toshiharu Shirai; Hideji Nishida; Hideki Murakami; Tamon Kabata; Norio Yamamoto; Koji Watanabe; Junsuke Nakase
Journal:  J Orthop Sci       Date:  2012-07-18       Impact factor: 1.601

10.  Antibiofilm properties of silver and gold incorporated PU, PCLm, PC and PMMA nanocomposites under two shear conditions.

Authors:  Shilpa N Sawant; Veerapandian Selvaraj; Veluchamy Prabhawathi; Mukesh Doble
Journal:  PLoS One       Date:  2013-05-13       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.