Literature DB >> 10571215

Comparison of prostate cancer treatment in two institutions: a quality control study.

C Rasch1, P Remeijer, P C Koper, G J Meijer, J C Stroom, M van Herk, J V Lebesque.   

Abstract

PURPOSE: To minimize differences in the treatment planning procedure between two institutions within the context of a radiotherapy prostate cancer trial. PATIENTS AND METHODS: Twenty-two patients with N0 M0 prostate cancer underwent a computed tomography (CT) scan for radiotherapy treatment planning. For all patients, the tumor and organs at risk were delineated, and a treatment plan was generated for a three-field technique giving a dose of 78 Gy to the target volume. Ten of the 22 cases were delineated and planned in the other institution as well. The delineated volumes and dose distributions were compared.
RESULTS: All treatments fulfilled the trial criteria. The mean volume ratio of the gross tumor volumes (GTVs) in both institutions was 1.01, while the mean volume ratio of the planning target volumes (PTVs) was 0.88. The three-dimensional (3D) PTV difference was 3 mm at the prostate apex and 6-8 mm at the seminal vesicles. This PTV difference was mainly caused by a difference in the method of 3D expansion, and disappeared when applying an improved algorithm in one institution. The treated volume (dose > or =95% of isocenter dose) reflects the size of the PTV and the conformity of the treatment technique. This volume was on average 66 cm3 smaller in institution A than in institution B; the effect of the PTV difference was 31 cm3 and the difference in technique accounted for 36 cm3. The mean delineated rectal volume including filling was 112 cm3 and 125 cm3 for institution A and B, respectively. This difference had a significant impact on the relative dose volume histogram (DVH) of the rectum.
CONCLUSION: Differences in GTV delineation were small and comparable to earlier quantified differences between observers in one institution. Different expansion methods for generation of the PTV significantly influenced the amount of irradiated tissue. Strict definitions of target and normal structures are mandatory for reliable trial results.

Entities:  

Mesh:

Year:  1999        PMID: 10571215     DOI: 10.1016/s0360-3016(99)00280-1

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Comparison of different contouring definitions of the rectum as organ at risk (OAR) and dose-volume parameters predicting rectal inflammation in radiotherapy of prostate cancer: which definition to use?

Authors:  Mirko Nitsche; Werner Brannath; Matthias Brückner; Dirk Wagner; Alexander Kaltenborn; Nils Temme; Robert M Hermann
Journal:  Br J Radiol       Date:  2016-12-12       Impact factor: 3.039

2.  Clinical evaluation of soft tissue organ boundary visualization on cone-beam computed tomographic imaging.

Authors:  Elisabeth Weiss; Jian Wu; William Sleeman; Joshua Bryant; Priya Mitra; Michael Myers; Tatjana Ivanova; Nitai Mukhopadhyay; Viswanathan Ramakrishnan; Martin Murphy; Jeffrey Williamson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-09       Impact factor: 7.038