Literature DB >> 10569709

Preclinical cost analysis of orthopaedic implants: a custom versus standard cementless femoral component for revision total hip arthroplasty.

P B Chang1, B H Robie, D L Bartel.   

Abstract

A preclinical cost analysis method was introduced to assess the cost effectiveness of using a custom implant instead of standard "off-the-shelf" implants for revision total hip arthroplasty. Finite element models of proximal femur-implant systems were constructed and an array of environmental factors, including loads and bone properties, was incorporated into a computer experiment to evaluate relative motion between implant and bone. Implant performance related cost was then determined from relative motion measures using a quality loss function. Unit manufacturing cost was added to implant performance cost to determine the cost difference between the two implants. The reduction in relative motion achieved by the custom implant with respect to an equivalent-lengthed standard implant justified its additional unit manufacturing costs. In response to these results and suggestions by surgeons, we increased the length of the standard implant by 50 mm and performed an identical series of analyses. We found that increasing the stem length to 120 mm substantially decreased the relative motion of the standard implant to values less than for the custom implant. This case study provides preliminary evidence that a surgical inventory consisting of longer-stemmed standard implants or modular distal stems is more cost effective than designing custom devices on a case-by-case basis. Additional design studies are warranted before generalizing such a claim.

Entities:  

Mesh:

Year:  1999        PMID: 10569709     DOI: 10.1016/s0021-9290(99)00097-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  The Adaptiva custom-made stem--our reasons for not using it anymore.

Authors:  Patrik Karl Reize; Nikolaus Wülker
Journal:  Int Orthop       Date:  2006-05-31       Impact factor: 3.075

2.  Outcomes of primary total hip arthroplasty using 3D image-based custom stems in unselected patients: a systematic review.

Authors:  A Nogier; I Tourabaly; S Ramos-Pascual; J H Müller; M Saffarini; C Courtin
Journal:  EFORT Open Rev       Date:  2021-12-10

3.  What Is the Survival of the Telescope Allograft Technique to Augment a Short Proximal Femur Segment in Children After Resection and Distal Femur Endoprosthesis Reconstruction for a Bone Sarcoma?

Authors:  Suraj Hindiskere; Eric Staals; Davide Maria Donati; Marco Manfrini
Journal:  Clin Orthop Relat Res       Date:  2021-08-01       Impact factor: 4.755

  3 in total