Storage temperatures of out-of-hospital medications.

J R Allegra1, J Brennan, V Lanier, R Lavery, B MacKenzie.   

Abstract

OBJECTIVES: To determine whether temperatures inside drug boxes used in the out-of-hospital setting are within the U.S. Pharmacopeia recommendations for "controlled room temperature," which is defined as a temperature maintained between 15 degrees C and 30 degrees C with a mean kinetic temperature less than 25 degrees C, and to determine whether time-temperature indicator labels can reliably monitor mean kinetic temperatures.
METHODS: Two methods were used to monitor temperatures: miniature electronic temperature recorders and color-changing time-temperature indicator labels. These were placed in drug storage boxes of advanced life support units over three summer months and two winter months.
RESULTS: In summer, the electronic recorders logged temperatures exceeding 30 degrees C in all drug storage boxes, ranging from 3% to 29% of the total time. The mean kinetic temperatures by location for the whole period ranged from 21 degrees C to 30 degrees C. In the winter, the electronic recorders logged temperatures exceeding 30 degrees C at one location 2% of the total time. There were significant temperature excursions below 15 degrees C at all locations, ranging from 16% to 90% of the total time. At one location, there were temperature readings below 0 degrees C for 9% of the total time. The mean kinetic temperatures obtained from the electronic recorders and the indicator labels differed by less than 1 degrees C.
CONCLUSIONS: This study demonstrates that out-of-hospital medications are subject to temperatures both above and below recommended storage temperatures. Time-temperature indicator labels can reliably monitor exposure to elevated temperatures.

Mesh:

Year:  1999        PMID: 10569380     DOI: 10.1111/j.1553-2712.1999.tb00110.x

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  3 in total

1.  How to transport veterinary drugs in insulated boxes to avoid thermal damage by heating or freezing.

Authors:  Johannes Horak; Astrid Haberleitner; Günther Schauberger
Journal:  BMC Vet Res       Date:  2017-05-25       Impact factor: 2.741

2.  Survey on transportation and storage of biological therapies by patients.

Authors:  Maira Arias Saavedra; Carolina Aimo; Jose Astudillo Andrade; Damaris Alvarez; Gabriel Sequeira; Eduardo Kerzberg
Journal:  Eur J Rheumatol       Date:  2019-04-01

3.  Mean kinetic temperature evaluations through simulated temperature excursions and risk assessment with oral dosage usage for health programs.

Authors:  David Jenkins; Aida Cancel; Thomas Layloff
Journal:  BMC Public Health       Date:  2022-02-14       Impact factor: 3.295

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.