Literature DB >> 10569365

Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws. Influence of screw length.

D M Stadelmaier1, W R Lowe, O A Ilahi, P C Noble, H W Kohl.   

Abstract

Blunt-threaded interference screws used for fixation of hamstring tendons in anterior cruciate ligament reconstructions provide aperture fixation and may provide a biomechanically more stable graft than a graft fixed further from the articular surface. It is unknown if soft tissue fixation strength using interference screws is affected by screw length. We compared the cyclic and time-zero pull-out forces of 7 x 25 mm and 7 x 40 mm blunt-threaded metal interference screws for hamstring graft tibial fixation in eight paired human cadaveric specimens. A four-stranded autologous hamstring tendon graft was secured by a blunt-threaded interference screw into a proximal tibial tunnel with a diameter corresponding to the graft width. Eight grafts were secured with a 25-mm length screw while the other eight paired grafts were secured with a 40-mm length screw. During cyclic testing, slippage of the graft occurred as the force of pull became greater with each cycle until the graft-screw complex ultimately failed. All grafts failed at the fixation site, with the tendon being pulled past the screw. There were no measurable differences in the mean cyclic failure strength, pull-out strength, or stiffness between the two sizes of screws. Although use of the longer screw would make removal technically easier should revision surgery be necessary, it did not provide stronger fixation strength than the shorter, standard screw as had been postulated.

Entities:  

Mesh:

Year:  1999        PMID: 10569365     DOI: 10.1177/03635465990270061501

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  12 in total

1.  Optimal screw diameter for interference fixation in a bone tunnel: a porcine model.

Authors:  M W J Morris; J L Williams; A J Thake; Y Lang; J N Brown
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-02-06       Impact factor: 4.342

2.  Interference screws should be shorter than the hamstring tendon graft in the bone tunnel for best fixation.

Authors:  Michael Stalder; Mazda Farshad; Jess G Snedeker; Dominik C Meyer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-21       Impact factor: 4.342

3.  Equal tension in all four strands of a semitendinosus graft with a low profile tibial fixation device (Cobra LFD).

Authors:  S Winge; P Dunn; B K O Engström
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-10-06       Impact factor: 4.342

4.  Initial fixation strength of a hybrid technique for femoral ACL graft fixation.

Authors:  Andre Weimann; Thore Zantop; Mirco Herbort; Michael Strobel; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-24       Impact factor: 4.342

5.  Anterior Cruciate Ligament Reconstruction with 4-Strand Hamstring Tendon Construct May be Biomechanically Superior to 5-Strand Hamstring Tendon Construct When Using Femoral Suspensory Fixation.

Authors:  Mia S Hagen; Woody Sorey; Ermyas Kahsai; Scott Telfer; Kenneth Chin; Christopher Y Kweon; Albert O Gee
Journal:  Arthrosc Sports Med Rehabil       Date:  2022-05-24

6.  Cortical femoral suspensory fixation using screw post in anatomic single-bundle anterior cruciate ligament reconstruction: a prospective study and mid-term outcome results.

Authors:  Ashraf Abdelkafy
Journal:  Int Orthop       Date:  2016-01-07       Impact factor: 3.075

7.  Fixation strength of a novel bioabsorbable expansion bolt for patellar tendon bone graft fixation: an experimental study in calf tibial bone.

Authors:  Stefan Piltz; Patrick Strunk; Ludger Meyer; Wolfgang Plitz; Guenter Lob
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-03-24       Impact factor: 4.342

8.  [Ligamentoplasty of the anterior cruciate ligament of the knee-joint in the athlete: retrospective study of 80 cases conducted in the Department of Orthopaedics in Tataouine, Tunisia].

Authors:  Mourad Hammami; Nizar Sahnoun
Journal:  Pan Afr Med J       Date:  2020-05-04

Review 9.  Adjustable Loop Femoral Cortical Suspension Devices for Anterior Cruciate Ligament Reconstruction: A Systematic Review.

Authors:  Sarvpreet Singh; Shalin Shaunak; Sebastian C K Shaw; John L Anderson; Vipul Mandalia
Journal:  Indian J Orthop       Date:  2020-01-13       Impact factor: 1.251

10.  Graft Retensioning Technique Using an Adjustable-Loop Fixation Device in Arthroscopic Anterior Cruciate Ligament Reconstruction.

Authors:  Joseph T Gamboa; Edward C Shin; Neil P Pathare; Patrick J McGahan; James L Chen
Journal:  Arthrosc Tech       Date:  2018-02-22
View more