G L Morris1, W M Mueller. 1. Department of Neurology, Medical College of Wisconsin, Milwaukee 53226, USA.
Abstract
OBJECTIVE: To perform an open-label, long-term efficacy and safety/tolerability study of vagus nerve stimulation (VNS) of 454 patients with refractory epilepsy. METHODS: Subjects were enrolled from five clinical trials of VNS between 1988 and 1995 after undergoing an implantation of a pulse generator in the chest and a left cervical vagus nerve-stimulating lead coil. Patients were assessed at 6-month intervals until device approval. Seizure frequencies, medication treatment, and adverse events (AEs) were recorded and entered into a database. RESULTS: A total of 454 patients were implanted, and 440 patients yielded assessable data. A > or =50% seizure reduction postimplantation occurred in 36.8% of patients at 1 year, in 43.2% at 2 years, and in 42.7% at 3 years. Median seizure reductions compared with baseline were 35% at 1 year, 44.3% at 2 years, and 44.1% at 3 years. Most common AEs postimplantation at 1 year were hoarseness (28%) and paraesthesias (12%), at 2 years were hoarseness (19.8%) and headache (4.5%), and at 3 years was shortness of breath (3.2%). Continuation rates were 96.7% at 1 year, 84.7% at 2 years, and 72.1% at 3 years. CONCLUSION: Long-term, open-label vagus nerve stimulation (VNS) provided seizure reduction similar to or greater than acute studies, for median reductions and for those reaching a > or =50% seizure reduction. VNS remained safe and well tolerated, with nearly three-quarters of the patients choosing to continue therapy.
OBJECTIVE: To perform an open-label, long-term efficacy and safety/tolerability study of vagus nerve stimulation (VNS) of 454 patients with refractory epilepsy. METHODS: Subjects were enrolled from five clinical trials of VNS between 1988 and 1995 after undergoing an implantation of a pulse generator in the chest and a left cervical vagus nerve-stimulating lead coil. Patients were assessed at 6-month intervals until device approval. Seizure frequencies, medication treatment, and adverse events (AEs) were recorded and entered into a database. RESULTS: A total of 454 patients were implanted, and 440 patients yielded assessable data. A > or =50% seizure reduction postimplantation occurred in 36.8% of patients at 1 year, in 43.2% at 2 years, and in 42.7% at 3 years. Median seizure reductions compared with baseline were 35% at 1 year, 44.3% at 2 years, and 44.1% at 3 years. Most common AEs postimplantation at 1 year were hoarseness (28%) and paraesthesias (12%), at 2 years were hoarseness (19.8%) and headache (4.5%), and at 3 years was shortness of breath (3.2%). Continuation rates were 96.7% at 1 year, 84.7% at 2 years, and 72.1% at 3 years. CONCLUSION: Long-term, open-label vagus nerve stimulation (VNS) provided seizure reduction similar to or greater than acute studies, for median reductions and for those reaching a > or =50% seizure reduction. VNS remained safe and well tolerated, with nearly three-quarters of the patients choosing to continue therapy.
Authors: Rodney W Roosevelt; Douglas C Smith; Richard W Clough; Robert A Jensen; Ronald A Browning Journal: Brain Res Date: 2006-09-07 Impact factor: 3.252
Authors: Jeffrey L Ardell; Heath Nier; Matthew Hammer; E Marie Southerland; Christopher L Ardell; Eric Beaumont; Bruce H KenKnight; J Andrew Armour Journal: J Physiol Date: 2017-09-30 Impact factor: 5.182
Authors: Navid Khodaparast; Seth A Hays; Andrew M Sloan; Tabbassum Fayyaz; Daniel R Hulsey; Robert L Rennaker; Michael P Kilgard Journal: Neurorehabil Neural Repair Date: 2014-02-18 Impact factor: 3.919