Literature DB >> 10561655

Comparison of visual and computerized interpretation of nonstress test results in a randomized controlled trial.

L A Bracero1, S Morgan, D W Byrne.   

Abstract

OBJECTIVE: This study tested the null hypothesis that the number of fetal surveillance tests and perinatal outcomes would not differ statistically between pregnancies randomized to visual or computerized interpretation of antepartum nonstress test results. STUDY
DESIGN: A prospective, randomized controlled trial was conducted, which required a sample size of 404 patients. By using a random-number table with assignment codes concealed in opaque envelopes, half of the patients were randomized to computerized interpretation of nonstress test results and half to standard visual interpretation of nonstress test results. The amount of antepartum testing and the perinatal outcome were measured and compared between the groups. Logistic regression analysis was used to control for maternal risk factors while morbidity differences between the 2 groups were assessed.
RESULTS: The 2 randomized groups were similar at baseline, but the computerized interpretation group had significantly fewer biophysical profiles compared with the visual interpretation group (1.3 +/- 1.8 vs 1.9 +/- 2.1; P =.002). The patients in the computerized interpretation group spent less time per test than patients in the visual interpretation group (12 vs 20 minutes; P =.038). After the 5 pregnancies with congenital anomalies were excluded, the overall perinatal outcome was similar in the 2 groups. The computerized interpretation group, however, had a slightly lower proportion of infants who required >/=2 days of neonatal intensive care (7.4% vs 12.4%; P =.086; odds ratio, 0.56; 95% confidence interval, 0.29-1.09). The average number of neonatal intensive care days was also slightly lower in the computerized interpretation group (0.4 vs 0.9; P =.105). Neither of these variables was statistically significant.
CONCLUSIONS: Computerized interpretation of nonstress test results is associated with fewer additional fetal surveillance examinations, less time spent in testing, and a similar length of stay in the neonatal intensive care unit compared with standard visual interpretation.

Entities:  

Mesh:

Year:  1999        PMID: 10561655     DOI: 10.1016/s0002-9378(99)70118-3

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  2 in total

Review 1.  Management of reported decreased fetal movements for improving pregnancy outcomes.

Authors:  G Justus Hofmeyr; Natalia Novikova
Journal:  Cochrane Database Syst Rev       Date:  2012-04-18

Review 2.  Antenatal cardiotocography for fetal assessment.

Authors:  Rosalie M Grivell; Zarko Alfirevic; Gillian M L Gyte; Declan Devane
Journal:  Cochrane Database Syst Rev       Date:  2015-09-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.