Literature DB >> 10561635

Umbilical vein blood flow determination in the ovine fetus: comparison of Doppler ultrasonographic and steady-state diffusion techniques.

H L Galan1, M Jozwik, S Rigano, T R Regnault, J C Hobbins, F C Battaglia, E Ferrazzi.   

Abstract

OBJECTIVE: This study was undertaken to assess the accuracy of triplex ultrasonographic measurement of venous umbilical blood flow in comparison with the steady-state diffusion technique and to determine the impact of cotyledon weight and number on umbilical blood flow. STUDY
DESIGN: Six late-gestation ewes with long-term catheter placement were studied for venous umbilical blood flow with the ethanol steady-state diffusion technique and with triplex-mode ultrasonography (color Doppler, pulsed-wave Doppler, and real-time ultrasonography). At necropsy the number and weight of the cotyledons serving each umbilical vein were recorded.
RESULTS: Umbilical blood flow determined by triplex-mode ultrasonography (207. 5 +/- 8.6 mL. kg(-1) fetus. min(-1)) was virtually identical to that determined with the steady-state diffusion technique (208.1 +/- 7.3 mL. kg(-1) fetus. min(-1); P =.9). When values were normalized for the weight or number of cotyledons serving each vein, there was no difference in umbilical blood flow between small and large umbilical veins in all the sheep.
CONCLUSIONS: Our study validates the accuracy of the triplex ultrasonographic method and provides justification for its use in future human investigations. In absolute terms umbilical blood flow frequently differs between the 2 veins. When expressed per number or mass of cotyledons, however, the umbilical blood flows are similar.

Entities:  

Mesh:

Year:  1999        PMID: 10561635     DOI: 10.1016/s0002-9378(99)70098-0

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  4 in total

1.  Placental TonEBP/NFAT5 osmolyte regulation in an ovine model of intrauterine growth restriction.

Authors:  Juan A Arroyo; Pastora Garcia-Jones; Amanda Graham; Cecilia C Teng; Frederick C Battaglia; Henry L Galan
Journal:  Biol Reprod       Date:  2012-03-30       Impact factor: 4.285

2.  Reliability and characteristics of ultrasound measurement of fetal umbilical venous blood flow volume according to the site of measurement.

Authors:  Seiji Kanazawa; Jin Muromoto; Katsusuke Ozawa; Masashi Mikami; Kohei Ogawa; Seiji Wada; Haruhiko Sago
Journal:  J Med Ultrason (2001)       Date:  2020-01-07       Impact factor: 1.314

3.  Centrality of the umbilical cord insertion in a human placenta influences the placental efficiency.

Authors:  M Yampolsky; Carolyn M Salafia; O Shlakhter; D Haas; B Eucker; J Thorp
Journal:  Placenta       Date:  2009-10-30       Impact factor: 3.481

4.  Hypoglycemia and the origin of hypoxia-induced reduction in human fetal growth.

Authors:  Stacy Zamudio; Tatiana Torricos; Ewa Fik; Maria Oyala; Lourdes Echalar; Janet Pullockaran; Emily Tutino; Brittney Martin; Sonia Belliappa; Elfride Balanza; Nicholas P Illsley
Journal:  PLoS One       Date:  2010-01-01       Impact factor: 3.240

  4 in total