Literature DB >> 10559828

A deterministic approach to automated stenosis quantification.

G Tommasini1, P Rubartelli, M Piaggio.   

Abstract

We developed a new approach to quantitative coronary angiography (QCA), which overcomes several limitations of available programs, such as dependence on operator input; limited tracking ability; fixed correction of the point spread function (PSF); and different calibration on empty vs. contrast-filled catheters. The program (Intelligent Images QCA, version 1.4) provides absolute reproducibility by deterministic, operator-independent identification of the skeleton and the edges of the coronary tree. The algorithm works as follows: application of a matched filter to emphasize selectively the coronary arteries; adaptive threshold binarization; binary thinning and skeletonization; perpendicular resampling with sub-pixel interpolation; derivative filtering; minimal cost edge detection; and automatic identification and quantification of the stenosis. Operator's interaction is restricted to definition of a region of interest; editing of either skeleton or edges is not allowed. PSF correction is fine-tuned to the actual frequency response of the imaging chain by calibration on a contrast-filled conical lucite phantom. Catheter calibration is carried out by a second derivative-based edge detection much less sensitive to the presence of contrast. In vitro phantom analysis (0. 5 to 5.0 mm) showed accuracy of 0.028-0.031 mm and precision of 0. 054-0.062 mm on nonmagnified images from the angio TV chain and the cine projector, respectively. In vivo evaluation on a series of consecutive diagnostic angiograms yielded correct contour detection of 70/73 stenoses (96%); interobserver intraframe MLD variability 0. 00 mm; correct tracking of catheter edges 100%; interobserver variation coefficient of catheter calibration 3.3%; and mean difference of calibration factor on contrast-filled vs. empty catheters 2.7%. This new approach significantly improves reproducibility with respect to conventional QCA, maintaining high accuracy, precision, and applicability. Cathet. Cardiovasc. Intervent. 48:435-445, 1999. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  1999        PMID: 10559828     DOI: 10.1002/(sici)1522-726x(199912)48:4<435::aid-ccd21>3.0.co;2-8

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  1 in total

1.  A novel approach for the detection of pathlines in X-ray angiograms: the wavefront propagation algorithm.

Authors:  Johannes P Janssen; Gerhard Koning; Patrick J H de Koning; Joan C Tuinenburg; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2002-10       Impact factor: 2.357

  1 in total