Literature DB >> 10556661

An enzyme thermistor-based assay for total and free cholesterol.

V Raghavan1, K Ramanathan, P V Sundaram, B Danielsson.   

Abstract

A method to evaluate the free (FC) and total cholesterol (TC) in human serum, bile and gallstone extract using an enzyme thermistor (ET)-based flow injection analysis (FIA) is presented. The cholesterol in high-density (HDL-C) and low density lipoprotein (LDL-C) have also been evaluated. A heparin functionalized Sepharose column was employed for the isolation of HDL and LDL fractions from serum. The estimation of cholesterol and its esters was based on their reaction with cholesterol oxidase (CO), cholesterol esterase (CE) and catalase (CAT). Three different enzyme columns, i.e. co-immobilized CO/CAT (column A), only CE (column B) and co-immobilized CO/CE/CAT (column C) were prepared by cross-linking the enzymes on glass beads using glutaraldehyde. Column A was used for estimating FC and column C was used for estimating total cholesterol (cholesterol plus esterified cholesterol). Column B was used as a pre-column which could be switched 'in' or 'out' in conjunction with column A for the estimation of TC or FC, respectively. A calibration between 1.0 and 8.0 mmol/l for FC and 0. 25 and 4.0 mmol/l for TC was obtained. For more than 2000 assays with the ET device a C.V. of less than 4% was obtained. The assay time was approximately 4 min per assay. The cholesterol estimations on the ET correlated well with similar estimations using a commercially available cholesterol diagnostic kit.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10556661     DOI: 10.1016/s0009-8981(99)00174-6

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  3 in total

Review 1.  Zinc Oxide-Based Self-Powered Potentiometric Chemical Sensors for Biomolecules and Metal Ions.

Authors:  Muhammad Israr-Qadir; Sadaf Jamil-Rana; Omer Nur; Magnus Willander
Journal:  Sensors (Basel)       Date:  2017-07-19       Impact factor: 3.576

2.  An InN/InGaN quantum dot electrochemical biosensor for clinical diagnosis.

Authors:  Naveed ul Hassan Alvi; Victor J Gómez; Paul E D Soto Rodriguez; Praveen Kumar; Saima Zaman; Magnus Willander; Richard Nötzel
Journal:  Sensors (Basel)       Date:  2013-10-15       Impact factor: 3.576

3.  Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum.

Authors:  Kusum Lata; Vikas Dhull; Vikas Hooda
Journal:  Biochem Res Int       Date:  2016-01-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.