Capillary isoelectric focusing of haemoglobin variants in the clinical laboratory.

M A Jenkins1, S Ratnaike.   

Abstract

For capillary isoelectric focusing (CIEF) to be accepted in the clinical laboratory, it must be reproducible and cost effective. The advent of polyAAEE coated capillaries (Bio-Rad Laboratories, Hercules, CA, USA) has provided the means of obtaining over 100 runs per capillary, something which previously had not always been possible with coated capillaries. Using the Clinical Data Management computer program on the BioFocus 2000 Capillary Electrophoresis System (Bio-Rad Laboratories), we have used a one-step salt mobilization to achieve focusing of haemoglobin variants. Washed red cells are diluted, haemolyzed and separated in the capillary at 8 kV using 1.3% Pharmalyte ampholytes (pH 6.6-7.7/pH 6-8 2:1) in 0.40% methylcellulose. The separated haemoglobins were detected by adsorption at 280 nm. Using published values of haemoglobin variants, we investigated the use of pI markers to confirm the pI of haemoglobin variants detected. CIEF, though more expensive than capillary electrophoretic separations of haemoglobin variants, has greater resolution due to the fact that the separation of variants from pI 6.95 to 7.42 occurs over 4 min, whereas the electrophoretic separation is over 60 s. CIEF is quicker than gel IEF, and shows real-time results as the sample is being processed. The potential for CIEF in the clinical laboratory is not limited to haemoglobin variants, and the technique should become increasingly popular in the near future.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10556659     DOI: 10.1016/s0009-8981(99)00167-9

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  6 in total

Review 1.  Clinical applications of capillary electrophoresis. Status at the new millennium.

Authors:  M A Jenkins
Journal:  Mol Biotechnol       Date:  2000-07       Impact factor: 2.695

2.  Capillary isoelectric focusing with pH 9.7 cathode for the analysis of gastric biopsies.

Authors:  Lauren M Ramsay; Nathan Cermak; Oluwatosin O Dada; Norman J Dovichi
Journal:  Anal Bioanal Chem       Date:  2011-04-02       Impact factor: 4.142

3.  Substituting Sodium Hydrosulfite with Sodium Metabisulfite Improves Long-Term Stability of a Distributable Paper-Based Test Kit for Point-of-Care Screening for Sickle Cell Anemia.

Authors:  Kian Torabian; Dalia Lezzar; Nathaniel Z Piety; Alex George; Sergey S Shevkoplyas
Journal:  Biosensors (Basel)       Date:  2017-09-20

4.  A Paper-Based Test for Screening Newborns for Sickle Cell Disease.

Authors:  Nathaniel Z Piety; Alex George; Sonia Serrano; Maria R Lanzi; Palka R Patel; Maria P Noli; Silvina Kahan; Damian Nirenberg; João F Camanda; Gladstone Airewele; Sergey S Shevkoplyas
Journal:  Sci Rep       Date:  2017-04-03       Impact factor: 4.379

5.  The effect of pH adjusted electrolytes on capillary isoelectric focusing assessed by high-resolution dynamic computer simulation.

Authors:  Anna Takácsi-Nagy; Ferenc Kilár; Wolfgang Thormann
Journal:  Electrophoresis       Date:  2021-12-21       Impact factor: 3.595

6.  Validation of a Low-Cost Paper-Based Screening Test for Sickle Cell Anemia.

Authors:  Nathaniel Z Piety; Xiaoxi Yang; Julie Kanter; Seth M Vignes; Alex George; Sergey S Shevkoplyas
Journal:  PLoS One       Date:  2016-01-06       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.