Literature DB >> 10553446

Use of infrared thermography to detect inflammation caused by contaminated growth promotant ear implants in cattle.

M F Spire1, J S Drouillard, J C Galland, J M Sargeant.   

Abstract

OBJECTIVE: To compare the infrared thermographic appearance of bovine ears that had received contaminated growth promotant implants with ears that had received clean implants and ears without implants.
DESIGN: Prospective study. ANIMALS: 32 yearling crossbred beef steers with a mean weight of 322 kg (708 lbs). PROCEDURE: Contaminated (n = 16) and clean (16) implants were placed in the ears of feedlot cattle. Nonimplanted (n = 32) ears served as a within-animal control for thermographic comparisons. Images of rostral and caudal surfaces were obtained during a 21-day period, using an infrared thermal imaging radiometer. Repeated measures ANOVA was used to determine the relationship between mean temperature in a zone on the rostral surface of the ear and at 3 locations (proximal, middle, distal) on the caudal surface of the ear (response variables) with treatment (ears with contaminated implants or clean implants vs control ears with no implants), time (repeated day of measurement), and interactions among these variables.
RESULTS: Significant temperature differences existed between ears with contaminated implants and control ears. Temperatures for ears with clean implants were significantly higher than control ears on day 2. At low ambient temperatures when the ears became wet, a greater temperature contrast was detected between ears with contaminated implants and control ears. CONCLUSIONS AND CLINICAL RELEVANCE: Thermal imaging of the ears of feedlot cattle is a noninvasive diagnostic tool that can be used to identify cattle with abscesses caused by contaminated growth-promotant implants.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10553446

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  4 in total

1.  The effect of perineural anesthesia on infrared thermographic images of the forelimb digits of normal horses.

Authors:  Layne C Holmes; Earl M Gaughan; Denise A Gorondy; Steve Hogge; Mark F Spire
Journal:  Can Vet J       Date:  2003-05       Impact factor: 1.008

2.  The use of infrared thermography as a rapid, quantitative, and noninvasive method for evaluation of inflammation response in different anatomical regions of rats.

Authors:  Ireneusz Całkosiński; Maciej Dobrzyński; Joanna Rosińczuk; Krzysztof Dudek; Aleksander Chrószcz; Katarzyna Fita; Robert Dymarek
Journal:  Biomed Res Int       Date:  2015-03-05       Impact factor: 3.411

3.  The use of infrared thermography to detect the stages of estrus cycle and ovulation time in anatolian shepherd dogs.

Authors:  Kemal Tuna Olğaç; Ergun Akçay; Beste Çil; Burak Mehmet Uçar; Ali Daşkın
Journal:  J Anim Sci Technol       Date:  2017-10-09

4.  Postoperative wound assessment in cattle: How reliable is the back hand palpation?

Authors:  Ioannis Proios; Marian Kusenda; Christian Seiler; Carsten Siewert; Hermann Seifert; Martin Kaske
Journal:  Ir Vet J       Date:  2021-06-16       Impact factor: 2.146

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.