Literature DB >> 10552321

Evaluation of a new monocortical screw for anterior cervical fusion and plating by a combined biomechanical and clinical study.

T Pitzen1, H J Wilke, W Caspar, L Claes, W I Steudel.   

Abstract

The purpose of this combined study was to evaluate the stability and safety of a new monocortical screw-plate system for anterior cervical fusion and plating (ACFP) according to Caspar in comparison with classical bicortical fixation. In the biomechanical part of the study two groups, each comprising six fresh human cadaveric spines (C4-C7), matched for bone mineral density, additionally resulting in almost the same mean age, were used. Range of motion and neutral zone were analyzed in flexion-extension, rotation (left, right) and lateral bending (left, right) using pure moments of +/- 2.5 Nm for each specimen in the intact state, after discectomy at C5/6 and after discectomy at C 5/6 followed by bone grafting plus plating (Caspar plates), with either monocortical or bicortical screws. For all three motion planes, no significant difference could be found between the new monocortical and the bicortical fixation techniques. The clinical part of the study was performed as a prospective study on 30 patients suffering from symptomatic degenerative cervical disc disease in one segment. At the latest follow-up, no hardware- or graft-related complications were seen in any of the patients. Following these findings monocortical screw fixation can be recommended for the majority of anterior cervical fusion and plating procedures in degenerative disease, making the procedure quicker, easier, and safer. Bicortical screw fixation still has specific indications for multilevel stabilization, poor bone quality (osteoporosis, rheumatoid disease - as bicortical oversized rescue screw), unstable spines (trauma, tumour) and in particular for the realignment of kyphotic deformities (restoration of the normal lordotic curve). Due to the design of the study the results apply only to surgical treatment of monosegmental degenerative disc disease at the time.

Entities:  

Mesh:

Year:  1999        PMID: 10552321      PMCID: PMC3611197          DOI: 10.1007/s005860050191

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  9 in total

1.  Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase.

Authors:  Wolfgang Lehmann; Michael Blauth; Daniel Briem; Ulf Schmidt
Journal:  Eur Spine J       Date:  2003-12-17       Impact factor: 3.134

2.  Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems.

Authors:  Wolfgang Lehmann; Daniel Briem; Michael Blauth; Ulf Schmidt
Journal:  Eur Spine J       Date:  2004-06-10       Impact factor: 3.134

3.  Factors affecting the interface of cervical spine facet screws placed in the technique by Roy-Camille et al.

Authors:  T R Pitzen; S Zenner; D Barbier; T Georg; W I Steudel
Journal:  Eur Spine J       Date:  2004-03-27       Impact factor: 3.134

4.  Autologous versus allogenic bone grafts in instrumented anterior cervical discectomy and fusion: a prospective study with respect to bone union pattern.

Authors:  Petr Suchomel; Pavel Barsa; Pavel Buchvald; Adam Svobodnik; Eva Vanickova
Journal:  Eur Spine J       Date:  2004-03-20       Impact factor: 3.134

5.  The cervical spine and its relation to anterior plate-screw fixation: a quantitative study.

Authors:  Sven R Kantelhardt; Joachim Oberle; Sharam Derakhshani; Erich Kast
Journal:  Neurosurg Rev       Date:  2005-04-05       Impact factor: 3.042

6.  Fusion and failure following anterior cervical plating with dynamic or rigid plates: 6-months results of a multi-centric, prospective, randomized, controlled study.

Authors:  Jan Stulik; Tobias Rainer Pitzen; Jan Chrobok; Sabine Ruffing; Jörg Drumm; Laurentius Sova; Ravel Kucera; Tomas Vyskocil; Wolf Ingo Steudel
Journal:  Eur Spine J       Date:  2007-08-08       Impact factor: 3.134

Review 7.  [Fractures of the cervical spine].

Authors:  H Laurer; A Sander; B Maier; I Marzi
Journal:  Orthopade       Date:  2010-03       Impact factor: 1.087

8.  [Operative stabilization of traumatic instabilities of the lower cervical spine. Experience with an angle instable anterior plate-screw system in 95 patients].

Authors:  D Daentzer; D-K Böker
Journal:  Unfallchirurg       Date:  2004-03       Impact factor: 1.000

9.  Biomechanical study of a novel self-locking plate system for anterior cervical fixation.

Authors:  Lifeng Lao; Qianyi Li; Guibin Zhong; Chao Song; Yuanchao Li; Mingze Xu; Zude Liu
Journal:  J Orthop Surg Res       Date:  2014-11-27       Impact factor: 2.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.