OBJECTIVES: The study was done to evaluate reliability of echocardiographic left ventricular (LV) mass. BACKGROUND: Echocardiographic estimation of LV mass is affected by several sources of variability. METHODS: We assessed intrapatient reliability of LV mass measurements in 183 hypertensive patients (68% men, 65 +/- 9 years) enrolled in the Prospective Randomized Enalapril Study Evaluating Regression of Ventricular Enlargement (PRESERVE) trial after a screening echocardiogram (ECHO) showed LV hypertrophy. A second ECHO was repeated at randomization (45 +/- 25 days later). Two-dimensional (2D)-guided M-mode or 2D linear measurements of LV cavity and wall dimensions were verified by one experienced reader. RESULTS:Mean LV mass was similar at first and second ECHO (243 +/- 53 vs. 241 +/- 54 g) and showed high reliability as estimated by intraclass correlation coefficient (RHO) = 0.93. Within-patient 5th, 10th, 90th and 95th percentiles of between-study difference in LV mass were -32 g, -28 g, +25 g and +35 g. Mean LV mass fell less from the first to the second ECHO than expected from a formula to predict regression to the mean (2 +/- 19 vs. 17 +/- 12 g, p < 0.001). Reliability was also high for LV internal diameter (RHO = 0.87), septal (RHO = 0.85) and posterior wall thickness (RHO = 0.83). Substantial or moderate reliability was observed for measures of LV systolic function and diastolic filling (RHO from 0.71 to 0.57). CONCLUSIONS: Left ventricular mass had high reliability and little regression to the mean; between-study LV mass change of +/-35 g or +/-17 g had > or = 95% or > or = 80% likelihood of being true change.
RCT Entities:
OBJECTIVES: The study was done to evaluate reliability of echocardiographic left ventricular (LV) mass. BACKGROUND: Echocardiographic estimation of LV mass is affected by several sources of variability. METHODS: We assessed intrapatient reliability of LV mass measurements in 183 hypertensivepatients (68% men, 65 +/- 9 years) enrolled in the Prospective Randomized Enalapril Study Evaluating Regression of Ventricular Enlargement (PRESERVE) trial after a screening echocardiogram (ECHO) showed LV hypertrophy. A second ECHO was repeated at randomization (45 +/- 25 days later). Two-dimensional (2D)-guided M-mode or 2D linear measurements of LV cavity and wall dimensions were verified by one experienced reader. RESULTS: Mean LV mass was similar at first and second ECHO (243 +/- 53 vs. 241 +/- 54 g) and showed high reliability as estimated by intraclass correlation coefficient (RHO) = 0.93. Within-patient 5th, 10th, 90th and 95th percentiles of between-study difference in LV mass were -32 g, -28 g, +25 g and +35 g. Mean LV mass fell less from the first to the second ECHO than expected from a formula to predict regression to the mean (2 +/- 19 vs. 17 +/- 12 g, p < 0.001). Reliability was also high for LV internal diameter (RHO = 0.87), septal (RHO = 0.85) and posterior wall thickness (RHO = 0.83). Substantial or moderate reliability was observed for measures of LV systolic function and diastolic filling (RHO from 0.71 to 0.57). CONCLUSIONS: Left ventricular mass had high reliability and little regression to the mean; between-study LV mass change of +/-35 g or +/-17 g had > or = 95% or > or = 80% likelihood of being true change.
Authors: James C S Spratt; Stephen J Leslie; Audrey White; Lynn Fenn; Colin Turnbull; David B Northridge Journal: Int J Cardiovasc Imaging Date: 2004-04 Impact factor: 2.357
Authors: G S Bleumink; A F C Schut; M C J M Sturkenboom; J A M J L Janssen; J C M Witteman; C M van Duijn; A Hofman; B H Ch Stricker Journal: Heart Date: 2005-02 Impact factor: 5.994
Authors: Senthil Selvaraj; Sanjiv J Shah; Mark J Ommerborn; Cheryl R Clark; Michael E Hall; Robert J Mentz; Saadia Qazi; Jeremy M Robbins; Thomas N Skelton; Jiaying Chen; J Michael Gaziano; Luc Djoussé Journal: Circ Heart Fail Date: 2017-06 Impact factor: 8.790
Authors: Marina De Marco; Eva Gerdts; Costantino Mancusi; Mary J Roman; Mai Tone Lønnebakken; Elisa T Lee; Barbara V Howard; Richard B Devereux; Giovanni de Simone Journal: Am J Cardiol Date: 2017-01-05 Impact factor: 2.778
Authors: Hassan A Chami; Richard B Devereux; John S Gottdiener; Reena Mehra; Mary J Roman; Emelia J Benjamin; Daniel J Gottlieb Journal: Circulation Date: 2008-05-05 Impact factor: 29.690
Authors: Daisuke Kamimura; Takeki Suzuki; Wanmei Wang; Matthew deShazo; John E Hall; Michael D Winniford; Iftikhar J Kullo; Thomas H Mosley; Kenneth R Butler; Michael E Hall Journal: Hypertens Res Date: 2018-06-15 Impact factor: 3.872
Authors: Stephen J Horgan; Chris J Watson; Nadia Glezeva; Pat Collier; Roisin Neary; Isaac J Tea; Niamh Corrigan; Mark Ledwidge; Ken McDonald; John A Baugh Journal: J Cardiovasc Transl Res Date: 2015-11-17 Impact factor: 4.132