Literature DB >> 10551234

MR imaging of the heart in patients after myocardial infarction: effect of increasing intersection gap on measurements of left ventricular volume, ejection fraction, and wall thickness.

Y Cottin1, C Touzery, F Guy, A Lalande, O Ressencourt, S Roy, P M Walker, P Louis, F Brunotte, J E Wolf.   

Abstract

PURPOSE: To determine the extent to which the number of planes imaged at magnetic resonance (MR) imaging could be reduced without modifying the calculated volume and thickness of the left ventricle.
MATERIALS AND METHODS: Sixty-one patients were examined after a myocardial infarction. The whole left ventricle was imaged by using 5-mm contiguous breath-hold cine MR short-axis sections with no gap (SAng) (two-dimensional fast low-angle shot sequence, 9/4.8 [repetition time msec/echo time msec]). The effect of omitting one section in two (short-axis sections with 5-mm gap [SA5 mm]) or two sections in three (short-axis sections with 10-mm gap [SA10 mm]) was studied.
RESULTS: In the comparison of SA5 mm or SA10 mm with respect to the reference SAng, the standard error of the estimate (SEE) for the diastolic volume did not exceed the 6.1% interobserver SEE, and the SEE for the ejection fraction remained lower than the 3% interobserver SEE. The measured wall thickness was not affected. In addition, six simple geometric models were compared with SAng and yielded an SEE of 9.5%-28.1% for the diastolic volume and 3.8%-13.3% for the ejection fraction.
CONCLUSION: In the study of left ventricles with heterogeneous contractility, short-axis imaging is more accurate than geometric modeling and permits wall thickness measurements when an intersection gap of 5 or 10 mm is used.

Entities:  

Mesh:

Year:  1999        PMID: 10551234     DOI: 10.1148/radiology.213.2.r99nv38513

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

Review 1.  MRI of left ventricular function.

Authors:  Frederick H Epstein
Journal:  J Nucl Cardiol       Date:  2007 Sep-Oct       Impact factor: 5.952

2.  Assessment of global left ventricular functional parameters: analysis of every second short-axis Magnetic Resonance Imaging slices is as accurate as analysis of consecutive slices.

Authors:  Daniel D Lubbers; Tineke P Willems; Pieter A van der Vleuten; Jelle Overbosch; Marco J W Götte; Dirk J van Veldhuisen; Matthijs Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2007-06-28       Impact factor: 2.357

3.  Major prognostic impact of persistent microvascular obstruction as assessed by contrast-enhanced cardiac magnetic resonance in reperfused acute myocardial infarction.

Authors:  Alexandre A Cochet; Luc Lorgis; Alain Lalande; Marianne Zeller; Jean-Claude Beer; Paul M Walker; Claude Touzery; Jean-Eric Wolf; François Brunotte; Yves Cottin
Journal:  Eur Radiol       Date:  2009-04-07       Impact factor: 5.315

4.  Impact of stress hyperglycemia on myocardial salvage in patients with ST-Elevation myocardial infarction: Cardiac magnetic resonance study.

Authors:  Taghreed Sayed Meshref; Refaat Fathi Abd El-Aal; Mahmoud Aly Ashry; Hisham Mostafa Imam; Ahmad B Elden
Journal:  Indian Heart J       Date:  2020-08-19

5.  Utility of Cardiac Magnetic Resonance to assess association between admission hyperglycemia and myocardial damage in patients with reperfused ST-segment elevation myocardial infarction.

Authors:  Alexandre Cochet; Marianne Zeller; Alain Lalande; Isabelle L'huillier; Paul M Walker; Claude Touzery; Bruno Verges; Jean-Eric Wolf; François Brunotte; Yves Cottin
Journal:  J Cardiovasc Magn Reson       Date:  2008-01-15       Impact factor: 5.364

6.  Cine and tagged cardiovascular magnetic resonance imaging in normal rat at 1.5 T: a rest and stress study.

Authors:  Jean-Luc Daire; Jean-Pascal Jacob; Jean-Noel Hyacinthe; Pierre Croisille; Karin Montet-Abou; Sophie Richter; Diomidis Botsikas; Matthieu Lepetit-Coiffé; Denis Morel; Jean-Paul Vallée
Journal:  J Cardiovasc Magn Reson       Date:  2008-11-03       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.