Literature DB >> 10551063

Cell culture tests for assessing the tolerance of soft tissue to variously modified titanium surfaces.

S Säuberlich1, D Klee, E J Richter, H Höcker, H Spiekermann.   

Abstract

The aim of our research project was to achieve an improvement in the integration of enossal dental implants in the region of peri-implantary soft tissue. Improvement in the adhesion of the gingiva of the surface of enossal implants was to be achieved by modification of the titanium surface. The effect of different modifications on the biocompatibility of the modified titanium surfaces was tested: sulfur dioxide plasma treatment of titanium; acetylene plasma treatment of titanium followed by sulfur dioxide plasma etching; plasma nitration of titanium; replacement of titanium by glycidoxypropyltrimethoxy silane; coating titanium with poly[(ethene-co-vinyl acetate)-graft-vinyl chloride] and coating titanium with fibronectin. Determination of the chemical composition of the surface was carried out using X-ray photospectroscopy. The adsorption of fibronectin at the surface of the titanium was tested using an Enzyme Linked Immunosorbent Assay. In selected in vitro tests with human gingival fibroblasts, cell morphology was assessed using scanning electron microscopy and light microscopy. Cell proliferation and protein synthesis, as well as the activity of mitochondrial dehydrogenases were evaluated. By means of centrifugation and by determining initial cell adhesion, the adhesion of gingival fibroblasts was investigated. According to the kind of modification made to the titanium surfaces, it was possible to observe differences in the cellular behavior of gingiva fibroblasts on the differently modified surfaces of the implants. Coating the titanium using fibronectin produced optimization of cell growth and improvement in the adhesion of gingiva fibroblasts to the implant surface. In contrast, modification of the titanium with poly[(ethene-co-vinyl acetate)-graft-vinyl chloride] generally resulted in a deterioration of the biocompatibility of the surface. A marked correlation between the cellular compatibility of the modified titanium and the surface modification made did not become apparent. One reason for this is the large number of parameters determining the interaction between implant and tissue.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10551063     DOI: 10.1034/j.1600-0501.1999.100505.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  8 in total

1.  In vitro assessment of the soft tissue/implant interface using porcine gingival explants.

Authors:  Aous A Abdulmajeed; Jaana Willberg; Stina Syrjänen; Pekka K Vallittu; Timo O Närhi
Journal:  J Mater Sci Mater Med       Date:  2015-01-15       Impact factor: 3.896

2.  Effects of coating a titanium alloy with fibronectin on the expression of osteoblast gene markers in the MC3T3 osteoprogenitor cell line.

Authors:  Bruce E Rapuano; Kyle M Hackshaw; Hannes C Schniepp; Daniel E MacDonald
Journal:  Int J Oral Maxillofac Implants       Date:  2012 Sep-Oct       Impact factor: 2.804

3.  Titanium alloy surface oxide modulates the conformation of adsorbed fibronectin to enhance its binding to α(5) β(1) integrins in osteoblasts.

Authors:  Bruce E Rapuano; Jani J E Lee; Daniel E MacDonald
Journal:  Eur J Oral Sci       Date:  2012-05-08       Impact factor: 2.612

4.  Surface oxide net charge of a titanium alloy: modulation of fibronectin-activated attachment and spreading of osteogenic cells.

Authors:  Bruce E Rapuano; Daniel E MacDonald
Journal:  Colloids Surf B Biointerfaces       Date:  2010-08-21       Impact factor: 5.268

5.  Heat and radiofrequency plasma glow discharge pretreatment of a titanium alloy: evidence [corrected] for enhanced osteoinductive properties.

Authors:  Bruce E Rapuano; Herman Singh; Adele L Boskey; Stephen B Doty; Daniel E MacDonald
Journal:  J Cell Biochem       Date:  2013-08       Impact factor: 4.429

6.  The biological seal of the implant-soft tissue interface evaluated in a tissue-engineered oral mucosal model.

Authors:  Wen L Chai; Ian M Brook; Anders Palmquist; Richard van Noort; Keyvan Moharamzadeh
Journal:  J R Soc Interface       Date:  2012-08-22       Impact factor: 4.118

7.  Heat or radiofrequency plasma glow discharge treatment of a titanium alloy stimulates osteoblast gene expression in the MC3T3 osteoprogenitor cell line.

Authors:  Bruce E Rapuano; Kyle Hackshaw; Daniel E Macdonald
Journal:  J Periodontal Implant Sci       Date:  2012-06-30       Impact factor: 2.614

8.  Immunohistochemical Results of Soft tissues Around a New Implant Healing-Abutment Surface: A Human Study.

Authors:  Barbara Ghinassi; Gianmaria D'Addazio; Angela Di Baldassarre; Beatrice Femminella; Giorgio Di Vincenzo; Maurizio Piattelli; Giulia Gaggi; Bruna Sinjari
Journal:  J Clin Med       Date:  2020-04-02       Impact factor: 4.241

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.