Literature DB >> 10550266

Grading internal carotid artery stenosis using B-mode ultrasound (in vivo study)

S Jmor1, T El-Atrozy, M Griffin, T Tegos, S Dhanjil, A Nicolaides, S Danjhl.   

Abstract

OBJECTIVE: to determine the value of percentage area and diameter reduction in grading ICA stenosis using colour-coded B-mode transverse ultrasonic images.
MATERIALS AND METHODS: measurement of the percentage area and diameter reduction of the common carotid, external carotid and internal carotid (at the point of maximum stenosis) were performed, using duplex scanning with colour-flow imaging preoperatively, in 33 patients (six patients were excluded). The duplex measurements were compared to the percentage area and diameter reduction from transverse section of the specimens. Peak systolic (PSV) and end-diastolic velocities (EDV) were measured at the proximal CCA and ICA within the jet of turbulence. A mm scale was placed next to the specimen block, which was captured by video. The area reduction was measured by playing the video and using the same duplex software.
RESULTS: linear-regression analysis of the percentage area reduction of the in vivo against the specimen measurements showed a good linear relationship (r=0.9047). The in vivo duplex measurements had 95% confidence interval (CI) of 8% (95% CI of diameter reduction 5%).
CONCLUSION: using the gold standard of fixed histological endarterectomy specimen, the results indicate that transverse image obtained with colour B-mode imaging is more appropriate in determining the degree of stenosis. Copyright 1999 Harcourt Publishers Ltd.

Entities:  

Mesh:

Year:  1999        PMID: 10550266     DOI: 10.1053/ejvs.1999.0884

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  4 in total

Review 1.  Does preoperative carotid stenosis screening reduce perioperative stroke in patients undergoing coronary artery bypass grafting?

Authors:  Khalil Masabni; Sajjad Raza; Eugene H Blackstone; Heather L Gornik; Joseph F Sabik
Journal:  J Thorac Cardiovasc Surg       Date:  2015-02-10       Impact factor: 5.209

2.  A Computer-Aided Diagnosis System for Measuring Carotid Artery Intima-Media Thickness (IMT) Using Quaternion Vectors.

Authors:  Uğurhan Kutbay; Fırat Hardalaç; Mehmet Akbulut; Ünsal Akaslan; Selami Serhatlıoğlu
Journal:  J Med Syst       Date:  2016-05-02       Impact factor: 4.460

3.  Reappraisal of velocity criteria for carotid bulb/internal carotid artery stenosis utilizing high-resolution B-mode ultrasound validated with computed tomography angiography.

Authors:  Wael E Shaalan; Carl M Wahlgren; Tina Desai; Giancarlo Piano; Christopher Skelly; Hisham S Bassiouny
Journal:  J Vasc Surg       Date:  2008-05-16       Impact factor: 4.268

4.  Measurement of carotid artery stenosis: correlation analysis between B-mode ultrasonography and contrast arteriography.

Authors:  Kyo Won Lee; Yang Jin Park; Young-Nam Rho; Dong-Ik Kim; Young-Wook Kim
Journal:  J Korean Surg Soc       Date:  2011-05-06
  4 in total