An efficient MR phosphorous spectroscopic localization technique for studying ischemic heart.

H Liu1, J Zhang.   

Abstract

To obtain the spatially resolved (31)P spectroscopic image from myocardium during an acute myocardium ischemia at a high signal-to-noise ratio (SNR) in a very limited time window, we have exploited the spatial variation of the radiofrequency (RF) field produced by a single loop transmit/receive (TR) RF coil along its axis for spatial discrimination. By incrementally lengthening the duration of a square RF excitation pulse, the positional information can be systematically encoded as harmonics of various orders in MR signal. In the in vivo open-chest animal experiment, this RF coil was surgically sutured onto the epicardial surface of the left ventricular (LV) wall over the region perfused by the left anterior descending coronary artery. Using only 17 encoding steps, we have obtained one-dimensional (31)P spectroscopic images from both a multiple-layer phosphor phantom and an in vivo LV myocardium. In the animal study, the cardiac gating is used with respiratory synchronization. The MR data were only collected during the end diastole phase of the cardiac cycle (cardiac and respiratory synchronized) with an effective sequence repetition time (TR) of 6 seconds (to ensure the complete relaxation of the phosphorous magnetization). The total acquisition time for a complete experiment is about 10 minutes. Prior to the CSI reconstruction process, the raw data matrix was zero-filled in the spatial dimension. The spatially resolved metabolite map exhibited all the metabolite peaks including creatine phosphate and adenosine triphosphate. At the layer of endocardium, two peaks corresponding to 2, 3-diphosphoglycerate, which is contained in the erythrocytes, were clearly seen in the LV wall. Also, the method allows compensation in both volume and coil sensitivity variations for the resulting spectra. All results have demonstrated that it is an efficient nuclear magnetic resonance method capable of obtaining high-quality (31)P spectroscopic images with both excellent spatial localization and SNR in the research of cardiac ischemia. J. Magn. Reson. Imaging 1999;10:892-898. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  1999        PMID: 10548804     DOI: 10.1002/(sici)1522-2586(199911)10:5<892::aid-jmri39>3.0.co;2-x

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  Novel strategy for measuring creatine kinase reaction rate in the in vivo heart.

Authors:  Qiang Xiong; Qinglu Li; Abdul Mansoor; Mohammad Nurulqadr Jameel; Fei Du; Wei Chen; Jianyi Zhang
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-06-26       Impact factor: 4.733

2.  Initial results of cardiac imaging at 7 Tesla.

Authors:  C J Snyder; L DelaBarre; G J Metzger; P-F van de Moortele; C Akgun; K Ugurbil; J T Vaughan
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

3.  Transmural distribution of metabolic abnormalities and glycolytic activity during dobutamine-induced demand ischemia.

Authors:  Mohammad N Jameel; Xiaohong Wang; Marcel H J Eijgelshoven; Abdul Mansoor; Jianyi Zhang
Journal:  Am J Physiol Heart Circ Physiol       Date:  2008-04-18       Impact factor: 4.733

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.