Literature DB >> 10548659

Three-dimensional transcranial color-coded sonography of cerebral aneurysms.

C Klötzsch1, A Bozzato, G Lammers, M Mull, B Lennartz, J Noth.   

Abstract

BACKGROUND AND
PURPOSE: The role of 2-dimensional transcranial color-coded sonography (2D-TCCS) as a diagnostic tool in cases of vascular alteration is unquestioned. The skill of the operator, however, may be responsible for some intertrial variability. The clinical value of a new, workstation-based, 3D reconstruction system for TCCS was evaluated in patients with intracranial aneurysms.
METHODS: Thirty patients with 30 intracranial aneurysms were investigated (8 men, 22 women; mean+/-SD age 54+/-17 years). The TCCS examinations were performed with a 2-MHz probe using the power mode. The 3D system (3D-Echotech, Germany) consisted of an electromagnet, which induced a low-intensity magnetic field near the head of the patient. A magnetic position sensor was attached to the ultrasound probe and transmitted the spatial orientation of the probe to a workstation, which also received the corresponding 2D-images from the video-port of the duplex machine. The echo contrast enhancer D-galactose (Levovist, Schering, Germany) was used in all patients to improve the signal-to-noise ratio. All patients underwent presurgical digital subtraction angiography (DSA) to demonstrate the aneurysm.
RESULTS: Twenty-nine of 30 angiographically proven intracranial aneurysms (97%) were detected by 3D-TCCS. The aneurysmal diameter estimated by DSA ranged from 3 to 16 mm (mean 7. 2+/-3.6 mm). A comparison of the 3 main diameters of each aneurysm revealed a correlation coefficient of 0.95 between DSA and 3D-TCCS. The 3D determination of the aneurysmal size by 2 experienced sonographers correlated with 0.96.
CONCLUSIONS: 3D-TCCS is a new, noninvasive method to investigate intracranial aneurysms. The differentiation between artifacts and true changes of the vessel anatomy is much easier in 3D-TCCS than in conventional 2D-TCCS. The new method yields an excellent correlation with the gold standard, DSA. Because the same 3D-TCCS data can be postprocessed by different investigators, it may be possible to improve reproducibility and increase the objectivity of transcranial color-coded duplex sonography.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10548659     DOI: 10.1161/01.str.30.11.2285

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  3 in total

1.  Real-time 3-D contrast-enhanced transcranial ultrasound and aberration correction.

Authors:  Nikolas M Ivancevich; Gianmarco F Pinton; Heather A Nicoletto; Ellen Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2008-04-18       Impact factor: 2.998

2.  Contrast-enhanced three-dimensional transcranial color-coded sonography of intracranial stenoses.

Authors:  Christof Klötzsch; Alessandro Bozzato; Gero Lammers; Michael Mull; Johannes Noth
Journal:  AJNR Am J Neuroradiol       Date:  2002-02       Impact factor: 3.825

3.  Improved visualization of intracranial vessels with intraoperative coregistration of rotational digital subtraction angiography and intraoperative 3D ultrasound.

Authors:  Dino Podlesek; Tobias Meyer; Ute Morgenstern; Gabriele Schackert; Matthias Kirsch
Journal:  PLoS One       Date:  2015-03-24       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.