Literature DB >> 10548300

Relationship between circulating antigen level and morbidity in Schistosoma mansoni-infected children evaluated by ultrasonography.

M M Hassan1, M H Hegab, S Z Soliman, O A Gaber, M M Shalaby, F M Kamel.   

Abstract

Ninety-eight Schistosoma mansoni-infected children from an endemic area in Sharkia Governorate, Egypt were evaluated by abdominal ultrasonography to determine liver and spleen sizes, grade of periportal fibrosis, and splenic vein diameter. Circulating antigen levels were measured using a double sandwich ELISA in which the sensitivity was 91.8% and specificity was > 99%, with no evidence of cross-reactivity with other parasites. No significant relationship was observed between antigen level and clinical stages of the disease as assessed by physical examination (P > 0.05). When ultrasound was used to stage disease, the mean antigen level was significantly higher among hepatosplenic cases than intestinal cases (P < 0.05). No difference in mean antigen levels were found between the splenic and hepatic cases. Furthermore, a direct correlation (P < 0.01) was observed between antigen level and disease severity as monitored by ultrasonography. Antigen level showed a positive correlation with the degree of periportal fibrosis (P < 0.05). Moreover, a significant increase in the percent of children who were antigen positive (> 80 ng/ml) was found in those with more severe periportal fibrosis (P < 0.001). The findings suggest that ultrasonography along with measurement of circulating antigen levels predict morbidity in schistosomiasis mansoni.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10548300     DOI: 10.4269/ajtmh.1999.61.635

Source DB:  PubMed          Journal:  Am J Trop Med Hyg        ISSN: 0002-9637            Impact factor:   2.345


  6 in total

1.  Comparative evaluation of Schistosoma mansoni, Schistosoma intercalatum, and Schistosoma haematobium alkaline phosphatase antigenicity by the alkaline phosphatase immunoassay (APIA).

Authors:  I M Cesari; D E Ballén; L Mendoza; A Ferrer; J-P Pointier; M Kombila; D Richard-Lenoble; A Théron
Journal:  Parasitol Res       Date:  2014-01-23       Impact factor: 2.289

Review 2.  Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas.

Authors:  Eleanor A Ochodo; Gowri Gopalakrishna; Bea Spek; Johannes B Reitsma; Lisette van Lieshout; Katja Polman; Poppy Lamberton; Patrick M M Bossuyt; Mariska M G Leeflang
Journal:  Cochrane Database Syst Rev       Date:  2015-03-11

3.  Utility of Schistosoma bovis adult worm antigens for diagnosis of human schistosomiasis by enzyme-linked immunosorbent assay and electroimmunotransfer blot techniques.

Authors:  J Pardo; C Carranza; M C Turrientes; J L Pérez Arellano; R López Vélez; V Ramajo; A Muro
Journal:  Clin Diagn Lab Immunol       Date:  2004-11

4.  Recent Advances in Schistosomiasis.

Authors:  G. Richard Olds; Srinivasan Dasarathy
Journal:  Curr Infect Dis Rep       Date:  2001-02       Impact factor: 3.725

5.  Schistosoma mansoni soluble egg antigens trigger erythrocyte cell death.

Authors:  Ravi S Kasinathan; Robert M Greenberg
Journal:  Cell Physiol Biochem       Date:  2010-10-29

6.  Experimental schistosomiasis, protective aspects of granulomatous reaction in the mouse liver.

Authors:  Stéphane Hanna; Bouchra Gharib; Hubert Lepidi; Jean-Claude Montet; Henri Dumon; Max de Reggi
Journal:  Parasitol Res       Date:  2005-03-10       Impact factor: 2.289

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.